30
Water Dispense-Push Button
1. Power Supply a) Off, blown fuse, or tripped breaker.
2. Control Board a) No power from control board to water dispense switch (5VDC) or
not reading signal.
b) No power to dispense water valve (24VAC).
3. Water Dispense Switch a) Defective.
4. Water Dispense Valve a) Water supply turned off.
b) Defective.
Water Dispense-Opti-Serve
1. Power Supply a) Off, blown fuse, or tripped breaker.
2. Control Board a) No power from control board to OS sensor (5VDC) or not reading
signal.
b) No power to water dispense valve (24VAC).
3. OS Sensor (infrared) a) Defective.
4. Water Dispense Valve a) Water supply turned off.
b) Defective.