Problem Possible Cause Remedy
[3]
Ice purge cycle will 
not start.
a) Water Control Relay  . Low water safety 
circuit open 
(bad contacts ).
. Replace.
b) Control Switch . Bad contacts. . Check for continuity and 
replace.
c) Bin Control . Open. . Bin full, check for 
continuity on proximity 
switch.
d) Control Board . Fails to operate gear 
motor relay.
. See "II.D.4. Control Board 
Check Procedure." 
e) Gear Motor Fuse . Blown. . Check gear motor 
amperage, bearing 
wear (see "V.F.. Upper 
Bearing Wear Check"), 
and supply voltage.
f) Gear Motor Thermal 
Protector
. Open. . Check gear motor 
bearings, supply voltage.
g) Gear Motor . Open windings. . Replace.
.
Auger coupling broke. . Replace.
3. Locked bearings. 3. Replace.
[4]
Freeze cycle will not 
start (compressor).
a) Gear Motor Protect 
Relay
. Open coil. . Replace.
.
Open contacts. . Replace.
b) Control Board  . Defective. . See "II.D.4. Control Board 
Check Procedure."
c) Starter (Start Relay) . Bad contacts. . Check for continuity and 
replace.
.
Coil winding open. . Replace.
3. Loose connections. 3. Tighten.
d) Start Capacitor or Run 
Capacitor
. Defective. . Replace.
e) Compressor . Power supply not 
within specications.
. Refer to nameplate and 
correct.
.
Wiring to compressor. . Check for loose or open 
connection, repair or 
replace.
3. Defective. 3. Replace.
4. Compressor locked 
and internal motor 
protector tripped.
4. Replace.
[5] All components 
run, but no ice is 
produced.
a) Refrigerant  . Low charge. . See "V.B. Service for 
Refrigerant Lines."
.
Refrigerant line or 
component restricted.
. Remove the restriction or 
component and replace 
the drier.
3. Air or moisture 
trapped.
3. Recover refrigerant, 
replace drier, evacuate, 
and recharge.
b) Expansion Valve . Bulb loose. . Secure bulb.
.
Operating erratically. . Check and replace.
c) Compressor . Defective. . Replace.