D. Defrost
1. Undercounter and Worktop Refrigerators
Off-Cycle Defrost: Undercounter and worktop refrigerators defrost naturally between run
cycles.
2. Prep Table Refrigerators and Undercounter and Worktop Freezers
Time-Initiated Defrost Cycle: Prep table refrigerators and undercounter and worktop
freezers have a defrost timer to control defrost cycle initiation and termination.
To initiate a manual defrost cycle follow the steps below.
1) Make sure the appliance is unplugged, then remove the rear panel. See Fig. 20.
2) Rotate the defrost timer cam clockwise
until it clicks. When the appliance is
plugged in it will start in a defrost cycle.
To bypass one defrost cycle, rotate the
defrost timer cam clockwise until it clicks
a 2
nd
time.
3) Replace the rear panel in its correct
position.
4) Plug the appliance into the electrical
outlet.
Rear Panel
Defrost
Timer Cam
Fig. 20