Service Manual
Table Of Contents
- Important Safety Information
- I. Construction and Refrigeration Circuit Diagram
- II. Sequence of Operation and Service Diagnosis
- III. Controls and Adjustments
- IV. Refrigeration Circuit and Component Service Information
- V. Maintenance
- VI. Preparing the Appliance for Periods of Non-Use
- VII. Disposal
- VIII. Technical Information
- A. Electrical and Refrigerant Data
- B. Wiring Diagrams
- 1a. Refrigerator: Undercounter and Worktop Auxiliary Code C-5(D) and Earlier
- 1b. Refrigerator: Undercounter and Worktop Auxiliary Code C-5(E) and Later
- 2a. Refrigerator: Prep Table Auxiliary Code C-5(D) and Earlier
- 2b. Refrigerator: Prep Table Auxiliary Code C-5(E) and Later
- 3a. Freezer: All Auxiliary Code C-5(D) and Earlier
- 3b. Freezer: All Auxiliary Code C-5(E) and Later
19
1. Appliance Not Cooling
Appliance Not Cooling - Possible Cause
1.
Power Supply
a)
Unplugged, blown fuse, or tripped or defective circuit breaker.
b)
Loose connection.
c)
Not within specications.
2.
Power Cord and Plug
a)
Loose connection.
b)
Defective.
3.
Wiring
a)
Loose connection or open.
b)
Faulty.
4.
Evaporator Fan
a)
Defective.
b)
Fan blade binding.
5.
Compressor External Protector
a)
Dirty condenser.
b)
Condenser fan not operating.
c)
Defective.
d)
Start relay defective.
e)
Low charge.
f)
Start capacitor (if applicable) defective.
6.
Compressor
a)
Defective.
7.
Condenser
a)
Dirty.
8.
Evaporator
a)
Dirty or frozen up.
9.
Refrigerant/Refrigerant Lines
a)
Gas leak.
b)
Refrigerant lines or components restricted.
10.
High-Pressure Switch
CRMR60 and CRMR72 prep
table, CRMF48(-01)(-W)(-W01),
and CRMF60(-W)
a)
Dirty condenser.
b)
Ambient temperature too warm.
c)
Condenser fan not operating.
d)
Refrigerant overcharge.
e)
Refrigerant lines or components restricted.
f)
Bad contacts.
11.
Thermostatic Expansion Valve
(not adjustable)
CRMF48(-01)(-W)(-W01)
(auxiliary codes A-5 and B-5)
a)
Defective.
2. Evaporator is Frozen Up
Evaporator is Frozen Up - Possible Cause
1.
Evaporator
a)
Dirty.
2.
Evaporator Fan
a)
Defective.
b)
Fan blade binding.
3.
Refrigerant Charge
a)
Low.
4.
Defrost Heater (freezer)
a)
Defective.
5.
Defrost Timer (prep table and freezer)
a)
Defective.
6.
Defrost Safety Thermostat Open
(freezer)
a)
Defective.
7.
Thermostatic Expansion Valve
(not adjustable)
CRMF48(-01)(-W)(-W01)
(auxiliary codes A-5 and B-5)
a)
Defective.