Service Manual

32
VIII. Technical Information
A. Electrical and Refrigerant Data
Model
AC Supply
Voltage Amperes
Design
Pressure
(PSIG)
Refrigerant
(oz.)
HIGH LOW 134a
CPT46(-D) 115/60/1 3.7 290 120 6.5
CPT67(-D), CPT93(-D) 115/60/1 5.5 290 120 11. 6
CRES36 115/60/1 4.3 330 120 8.5
CRES49 115/60/1 3.7 330 120 8.5
CRES72 115/60/1 4.3 330 120 8.5
CRES85 115/60/1 4.3 330 120 8.5
CRES98 115/60/1 4.3 330 120 8.5
See the nameplate for electrical and refrigeration specications. The nameplate is located
inside the cabinet.
We reserve the right to make changes in specications and design without prior notice.