Data Sheet
E7BX
Ÿ Simple to install and use
Ÿ Boost period adjustable between 0 and 120 minutes
Ÿ Neon indicator shows when boost timer is running
Ÿ Can be used with one or two immersion heaters
Ÿ Suits earth-leakage circuit breaker installations
Specification
CONTACT RATING 13 Amps 230V AC
Suitable for
immersion heaters up
to 3kW
CONTACT TYPE Disconnection to 'off
peak' immersion
heater on double-pole
switch
POWER SUPPLY 230 V 50Hz
POLLUTION DEGREE Degree 2
ENCLOSURE PROTECTION IP30
SHOCK PROTECTION Class 1
LIVE PARTS Enclosed
OPERATING TEMPERATURE 0 °C to 35 °C
RANGE
TIMER BOOST DURATION 0-120 minutes
DIMENSIONS 170 x 115 x 56 mm
BRITISH STANDARDS Designed to meet BS-
EN 60730-2-7
BEAB APPROVED
South Bristol Park, Roman Farm Road, Bristol BS4 1UP
t: +44 117 978 8700 | f: +44 117 9788701 | e: sales@horstmann.co.uk | www.horstmann.co.uk
Horstmann is a trading name of Secure Controls (UK) Ltd., a wholly owned subsidiary of Secure Holdings PTE Ltd.
Registered office: Secure House, Moorside Road, Winnall Trading Estate, Winchester, Hampshire, SO23 7RX. Registered in England No. 457553
© January 2013: Secure Controls (UK) Ltd: All rights reserved. The company reserves the right to alter product specifications without notice.
Part No. P81260 Issue 1