Manual

6
Step 2: Changing the Sub-Plate.
(This step is necessary only if you are installing the case feeder to an existing
press, with a serial number lower than 07000.) The new Sub-Plate (Part
Number 398309) is sold separately. The new priming system (Part Number
095210) is also sold separately for presses with serial # prior to 07000.
Raise the Eject Wire (#46) to move it out of the way.
Use a 9/16” end wrench to remove the bolt holding down the shell plate and
remove the shell plate.
Remove the case retainer spring.
Remove the primer feed assembly.
Unhook the extension spring from the primer slide and remove it from the Sub-
Plate (#44).
Remove the primer slide from the Sub-Plate.
Figure 2: Spent primer tubes dismantle / assembly.
Place the spent primer assembly tool in the bottom of the spent primer tube. Take
a pair of pliers or vise grips and clamp onto the spent primer tube approximately
¼” from the end and tap the pliers with a hammer to remove the spent primer
tube. Be careful not to lose the Counter Balance spring.
See Figure 2 for more details.
Raise the ram to the top of the stroke and “Block” it into place