Instructions / Assembly

13
Operating (continued)
WARNING: A leak test must be performed annually or if a part of the gas system is replaced.
LEAK TESTING OPERATION
If NO bubbles appear at any connection, the connections are secure.
NOTE: Whenever gas connections are loosened or removed, y
WARNING: Never use an open flame to check for gas leaks. Be certain no sparks or open flames are in the area
while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to property, serious
bodily injury, or death.
LEAK TESTING:
1, Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing soap with three parts water.
2, Make sure all fire pit and light valves are OFF
3, Apply several drops of solution where hose attaches to regulator.
4, Apply several drops of solution where regulator connects to cylinder.
5, Turn cylinder valve ON.
If bubbles appear at any connection, there is a leak.
1, Turn cylinder valve OFF.
2, If leak is at hose/regulator connection: tighten connection and perform another leak test.
3, If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another leak test.
ou must perform a complete leak test .
Hose/Regulator
Connection
Regulator/Cylinder
Connection