User's Manual
at the same time, and other part become gray.. when choosing timing or touching off mode
Reader can set the parameter of radio frequency timer and communication interface. If choosing
touching off mode, ,it can set the parameter of the trigger. We will describe them one by on as
the following.
setting interface
Users can set the power and frequency of the radio frequency according application need. The
largest power parameter can be 30dBm.You can choose China standard(920MHZ~925MHZ) or
FCC(902MHZ~928MHZ)as the frequency of radio frequency, other frequency bands need
customize.
antenna setting
When using multicenter readers, you can choose antenna,, Choosing the corresponding antenna
in the check box means antenna invocation.
Read indicate:
Buzzer and LED are optinal, for reader to choose,users can choose them according to demand.
Timing interval:
this frame includes setting the frequency of reading tag(namely setting time for cycle reading)
and the interfacing identification. Setting time for cycle reading can be 10ms`1000ms.Users can
choose interfacing identification and set the effective time for interfacing identification .If no
need of setting effective time, fill in ¡°0¡±instead.
Communication out port parameter setting:
Setting data out of communication pork and other agreement .When choosing RS485
communication agreement, Syns agreement and common transmission agreement are optional.
The format of common transmission agreements are like the predescription.. Please make
reference to the Syns controller information about Syns agreement.
Wiegand setting:
When choosing Wiegand interface ,you can choose Wiegand26 or Wiegand34 agreement.
Picture 10 interface setting
RS485 setting: