Installation Guide
Table Of Contents
10 / 16 HONG KONG KONING INDUSTRIAL LIMITED
Tel:0086-755-2906 9062
E-mail:rick@wisdomfer.com
W400/200 SERIES INSTALLATION GUIDE
each other (for example: the coverage area is in floor1 and floor2, we should mount the
donor antenna at over 4 floors. If there are no floor, you can calculate at one floor of 4
meter, try to raise the height of donor antenna.
b) Horizontally distance: the distance between donor antenna and sever antenna keep
over 20-30 meters, better separated by wall
c) Horizontally and vertical combination: presume above two ways fail, combine them.
d) Note: donor antenna and sever antenna unable line -of-sight for each other (on other
words, no matter where sever antenna can’t see donor antenna directly)
ꙬWarning: In order to void Oscillation, Donor antenna must keep reasonable distance with Service
antenna, not point the front of the outside antenna toward the service antenna.
4) Installing Lightning Protection
Install the Lightning Surge Protector (LSP) outside, in line with the coax cable from the outside
antenna, near where the coax cable from the outside antenna will enter the building. Connect the
Outside antenna cable to one of the connectors of the surge protector. Connect the other connector
on the LSP to the cable entering the building. Ensure the LSP is properly grounded as close to the
LSP as possible (ground wire not included).
ꙬWarning: We strongly recommend all installer to fit Lightning Surge Protector in site. Neither you
nor the antenna are far away any electric power lines.
5) Running Outside Antenna Cable
If you are mounting the outside antenna to the outside wall of your home or building, the simplest
way is to run the cable on the outside of the wall and attach it to the exterior of your home or office.
Then drill a hole through the wall where you want the cable to appear on the inside of the building.
Before drilling, make sure that there are no electrical outlets, sewer or water pipes, or electrical wiring
in the wall that you are about to drill through as this could potentially harm you or damage the
building.
Note: Existing TV cables already being used for another purpose cannot be shared with the cell
booster installation. After drilling the required hole, run the cable through and seal it with cable
bushings or a silicone-type sealant to enclose the hole that you have created. In some instances, it
may be possible to run the cable up into the fascia of the attic overhang. In this circumstance, the
cable will be accessible in the attic for further routing.