G W
YR RCK
Y2
C
Y
HEAT PUMP
CONVENTIONAL
AUX/E
G O/B
YRRCK
L
C
C
G
W
R
1.7 Connect wires
A 3TARTINGWITHTHE#7IREMATCHTHE
sticky tag on the wire to the terminal
labels.
Important! C wire is required and is the
primary power source. Without a C wire,
your thermostat will not power up.
View the Alternate Wiring videos at
wifithermostat.com/videos
B ,OOSENSCREWINSERTWIREONINSIDE
edge of terminal, then tighten screw.
C 6ERIFYWIREISFIRMLYSECUREDBYGENTLY
pulling on wire.
D 2EPEATSTEPSAqCFORALLOTHERWIRES
E 0USHANYEXCESSWIREBACKINTOTHEWALL
opening after all wires are installed.
Note: The wiring for your
application might be different
from the wiring shown above.
Labels don’t match or have heat pump system?
See User Guide.
Remove metal jumper
only if you
have both R and RC wires