Spec Sheet

Table Of Contents
THX9321 PRESTIGE
®
2.0 AND THX9421 PRESTIGE
®
IAQ WITH EIM
68-0311—07 92
The alert message that is displayed to the user.
The alert status (snoozed, dismissed, recovered)
User Interactions Log
The User Interactions Log can help a service technician
save time by determining if the issue is related to a system
problem or an accidental user error.
The User Interactions Log records the date and time for
most changes made by the user, whether made at the
thermostat or from a remote location (RedLINK Internet
Gateway, Portable Comfort Control, etc.). The log saves the
most recent 250 user changes, including:
Indoor Air Quality Settings
Maintenance Reminders
Temperature Settings
System/Fan Mode
Alerts (snoozed or dismissed)
Installer Setup
•Date/Time
Performance Logs
NOTE: Only applies to THX9421 Thermostat with an
Equipment Interface Module.
The Performance Log allows the service technician to
quickly check system performance over time to determine
if the equipment is operating as expected or if it requires
servicing.
The thermostat contains the following logs:
Cooling Performance Log
Heating Performance Log
Emergency Heat Performance Log
Run Time by Equipment Type
Indoor and Outdoor Conditions Log
Fig. 172.
The Performance Log records the following information:
Minimum and Maximum Delta T
Minimum and Maximum Discharge Temperature
Minimum and Maximum Return Temperature
Minimum and Maximum Outdoor Temperature and
Humidity
Minimum and Maximum Indoor Temperature and
Humidity
Run Time of Heating and Cooling per stage
Fig. 173.
You have the option to view this data in 4 different time
periods:
Hourly - saves data for the last 8 days.
Daily - saves data for the last 15 days.
Weekly - saves data for the last 8 weeks.
Monthly - saves data for the last 25 months.
NOTES:
Data is collected in the Emergency Heat Per-
formance Log only if the thermostat was set to
the “Emergency Heat” mode.
The Run Time by Equipment Type Log contains
the Total Run Time of each equipment type
since the last time it was reset.
The Minimum and Maximum Delta T, Dis-
charge Temperature and Return Temperature
are only shown in the log if the equipment ran
for at least 5 minutes during a cycle. If the
equipment ran for less than 5 minutes in every
cycle during a 1 hour period, the log will dis-
play “--°.
For Air to Air Heat Pumps, the Minimum Delta
T and Minimum Discharge Temperatures will
include defrost cycles in the log.