Spec Sheet

Table Of Contents
THX9321 PRESTIGE
®
2.0 AND THX9421 PRESTIGE
®
IAQ WITH EIM
65 68-0311—07
13190 Display Delta T Alerts
to User
No
Yes
Yes Both Yes No: The thermostat does NOT display a Delta T
alert to the user when a Delta T alert is entered
into the log.
Yes: The thermostat displays a Delta T alert to
the user when a Delta T alert is entered into the
log.
See “Delta T Alerts” beginning on page 89.
14000 Clock Format
12 hour
24 hour
12 Both No
14010 Daylight Saving Time
Off
On
On Both No Set to Off in areas that do not follow Daylight
Saving Time.
14020 Indoor Temperature
Display Offset
-3° F to 3° F (in 1° F increments)
0° F Both No 0° F - No difference in displayed temperature
and the actual room temperature.
The thermostat displays up to 3°F (1.5°C)
lower or higher than the actual measured
temperature.
14020 Indoor Humidity
Display Offset
-12% to 12% (in 1% increments)
0% Both No 0% - No difference in displayed humidity and
the actual room humidity.
The thermostat displays up to 12% lower or
higher than the actual measured humidity.
15000 Dealer Name
[Dealer Name]
None Both No
15000 Dealer Phone
[Dealer Phone]
None Both No
15010 Dealer Email Address
[Dealer Email Address]
None Both No
15010 Dealer Website
[Dealer Website]
None Both No
15020 Dealer Message
[Dealer Message]
None Both No
Table 4. Installer Setup (ISU) Table. (Continued)
ISU
Number
Installer Setup
Name Settings Default
Residential,
Commercial
or Both
Requires
EIM Notes