68-0311—07 52
6190 Custom Alert Name
View/Edit Custom Alert
View/Edit
Custom Alert
Both Yes Dry Contact Alerts require an EIM (Equipment
Interface Module).
Enter a name for the custom alert dry contact.
The thermostat displays this name including a
brief message (entered on the next screen - ISU
6200) when a dry contact device detects a
problem.
6200 Custom Alert
Message
View/Edit Custom Alert
View/Edit
Custom Alert
Both Yes Dry Contact Alerts require an EIM (Equipment
Interface Module).
Enter a message for the custom alert dry
contact. The thermostat displays this message
when a dry contact device detects a problem.
7000 Filter Type
None
Electronic Air Cleaner
Media
Media Both No
7020 Number of Air Filters
1 to 2
1BothNo
7110 Air Filter 1
Replacement
Reminder
Note: “1” is not
displayed if there is
only 1 filter.
Off
Run Time:
10, 20, 30, 45, 60, 90, 120, 150
days
Calendar:
30, 45, 60, 75 days
3, 4, 5, 6, 9, 12, 15 months
Off Both No
7110 Air Filter 2
Replacement
Reminder
Off
Run Time:
10, 20, 30, 45, 60, 90, 120, 150
days
Calendar:
30, 45, 60, 75 days
3, 4, 5, 6, 9, 12, 15 months
Off Both No
7120 Electronic Air
Cleaner Cell
Cleaning Reminder
Off
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
Off Both No
7120 Electronic Air
Cleaner Pre-Filter
Cleaning Reminder
Off
Calendar Months:
3, 4, 5, 6 months
Off Both No
7120 Electronic Air
Cleaner Post-Filter
Replacement
Reminder
Off
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
Off Both No
8000 Humidifier Type
None
Steam
Bypass or Fan Powered
None Both No
Table 4. Installer Setup (ISU) Table. (Continued)
ISU
Number
Installer Setup
Name Settings Default
Residential,
Commercial
or Both
Requires
EIM Notes