Spec Sheet
Table Of Contents
- Application
- Features
- Contents
- Specifications
- System Installation
- Installation Options
- Guidelines for Installing RedLINK Devices
- Installing Equipment Interface Module (if used)
- Wiring 24 Vac Common
- Selecting Discharge and Return Air Temperature Sensor Mounting Locations
- Selecting Return Air Temperature Sensor Mounting Location
- Installing Discharge and Return Air Temperature Sensors
- Selecting Thermostat Location
- Installing Wallplate
- Power Optional REDLINK™ Accessories
- Performing Initial Setup
- Linking Thermostat to Equipment Interface Module (if used)
- Linking RedLINK™ Accessories
- Completing Initial Setup
- Adding RedLINK Accessories to the Thermostat
- Locating the Connect Buttons on RedLINK Accessories
- Finding Your Password (Date Code) to Access Installer Options
- Installer Options
- Making Changes to Installer Setup
- Installer Tests
- Operation
- Setting the time/date
- Setting the fan
- Setting system mode
- Preset Energy-Saving Schedules
- Adjusting program schedules
- Overriding schedules: residential use
- Overriding schedules: commercial use
- Viewing equipment status
- Setting vacation hold: residential use
- Setting holiday/event schedules: commercial use
- Setting custom events: commercial use
- Setting holiday schedule: commercial use
- Setting holiday override: commercial use
- Initiating occupancy mode: commercial use
- Remote setback: commercial use
- Adjusting humidification settings
- Adjusting dehumidification settings: residential use
- Adjusting dehumidification settings: commercial use
- Adjusting ventilation settings
- Customizing screen color
- Setting preferences
- Cleaning the thermostat screen
- Adjusting security settings
- Viewing dealer information
- Advanced Features
- Installer options
- Using the temperature display
- Using the humidity display
- Universal Outputs (U1, U2, U3)
- Universal Inputs (S1, S2, S3, S4)
- Alerts and Diagnostics
- Heat Pump and Backup Heat Operation
- Indoor Air Quality (IAQ) Control
- IAQ Reminders
- Customizable Reminders
- USB Port
- Commercial Features
- Overriding schedules: commercial use
- Setting holiday/event schedules: commercial use
- Setting custom events: commercial use
- Setting holiday schedule: commercial use
- Setting holiday override: commercial use
- Initiating occupancy mode: commercial use
- Ramp Rates
- Custom Names
- Remote Setback
- Economizer and Time of Day (TOD) Operation
- Pre-Occupancy Purge
- Battery Replacement
- Optional Accessories
- Portable Comfort Control
- Remote Indoor Sensors
- Backup Control
- Replacing a Thermostat
- Replacing an Equipment Interface Module
- Wiring
- EIM Wiring Diagrams
- THX9321 Thermostat Wiring Diagrams
- THX9321 Thermostat Wiring Diagrams Using Universal Relays to Control Heating or Cooling
- Wiring IAQ Equipment or a Heat/Cool Stage to the Universal Terminals
- Economizer Module Wiring Diagrams
- Wiring C7089U1006 Outdoor Sensor
- Wiring guide — Wired Indoor Sensors
- Zoning
- Troubleshooting
- Regulatory Information
THX9321 PRESTIGE
®
2.0 AND THX9421 PRESTIGE
®
IAQ WITH EIM
68-0311—07 2
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further
information, or would like to comment on our products or services, please write or phone:
1. Your local Honeywell Environmental and Combustion Controls Sales Office (check white pages of your phone
directory).
2. Honeywell Customer Care
1985 Douglas Drive North
Golden Valley, Minnesota 55422-4386
3. http://customer.honeywell.com or http://customer.honeywell.ca
International Sales and Service Offices in all principal cities of the world. Manufacturing in Belgium, Canada, China,
Czech Republic, Germany, Hungary, Italy, Mexico, Netherlands, United Kingdom, and United States.
CONTENTS
Application ..................................................... 1
Specifications ................................................ 3
Ordering Information ..................................
Ordering Info
System Installation ...................................... 8
When Installing this Product... .............................. 8
Installing Equipment
Interface Module (if used) ........................................... 10
Wiring 24 Vac Common ............................................ 10
Selecting Discharge and Return Air Temperature Sen-
sor Mounting Locations ........................................... 10
Selecting Discharge and Return Air Temperature Sen-
sor Mounting Locations ............................................ 10
Selecting Return Air Temperature Sensor Mounting
Location ........................................................................... 11
Selecting Thermostat Location ............................. 12
Installing Wallplate ................................................... 12
Power Optional REDLINK™ Accessories ............. 14
Linking Thermostat to Equipment Interface Module
(if used) ......................................................................... 15
Linking RedLINK™ Accessories ............................. 16
Installer Tests ................................................ 66
Using the Equipment Test ....................................... 67
Using the Wireless Signal Strength Test ............. 67
Mounting Optional Accessories ............................ 68
Alerts and Diagnostics ................................ 86
Delta T Diagnostics ................................................... 86
Before You Set Up Delta T Diagnostics ................ 86
Setting up Alerts and Diagnostics ........................ 87
Delta T Alerts .............................................................. 89
Delta T Alerts and Utility Saver Switches ............ 90
Data Logs ..................................................................... 90
Alerts Log ......................................................................... 91
User Interactions Log ................................................. 92
Dry Contact Alerts ..................................................... 94
Heat Pump and Backup Heat Operation 100
Indoor Air Quality (IAQ) Control ............... 102
Humidification ........................................................... 102
Set up Humidification ................................................. 103
Control Humidification Level .................................. 104
Dehumidification - Residential ............................. 105
Set up Dehumidification With Cooling System 106
Set up Dehumidification
With Whole House Dehumidifier ............................ 107
Set up Dehumidification Away Mode .................... 109
Control Dehumidification Level .............................. 109
Dehumidification - Commercial ............................ 110
Set up Dehumidification With Cooling System 111
Set up Dehumidification With Dehumidifier ...... 112
Control Dehumidification Level .............................. 113
Ventilation ................................................................... 114
Set up Ventilation ......................................................... 115
IAQ Reminders .............................................. 118
Customizable Reminders .......................... 119
USB Port ......................................................... 121
Portable Comfort Control .......................... 131
Remote Indoor Sensors .............................. 132
Commercial Features .................................. 123
Ramp Rates ................................................................. 126
Custom Names ........................................................... 126
Remote Setback ......................................................... 126
Economizer and
Time of Day (TOD) Operation ..................................... 128
Pre-Occupancy Purge .............................................. 128
Staging Control .......................................................... 97
Optional Accessories .................................. 130
Troubleshooting ........................................... 163
Wiring .............................................................. 138
EIM Wiring Diagrams ............................................... 141
Geothermal Radiant Heat ....................................... 100
THX9321 Thermostat Wiring Diagrams .............. 144
THX9321 Thermostat Wiring Diagrams Using Univer-
sal Relays to Control Heating or Cooling ............ 145
Wiring IAQ Equipment or a Heat/Cool Stage to the
Universal Terminals .................................................. 152
Economizer Module Wiring Diagrams ................. 154
Wiring C7089U1006 Outdoor Sensor .................. 157
Wiring guide — Wired Indoor Sensors .................. 158
Regulatory Information ............................. 163