Technical Manual
XNX Universal Transmitter
Section 2 - Installation and Operation
38
Labels applied to the back of the POD identify each of the
connection points.
Note: Pins 2 and 4 of terminal block TB1 have no internal connection
on the personality board. When used with the terminal block jumpers,
pins 2 and 4 can provide additional 4-20mA connections or supply
power for daisy-chained units.
2.2.5
Foundation Fieldbus Wiring
Foundation Fieldbus connections to the XNX transmitter are
made through a pluggable terminal block on the Foundation
Fieldbus option board, shown in Figure 39. A simulation switch
(SW5)isincludedontheboardtoenable/disablesimulation
mode. Terminals 3-1 through 3-4 are provided to facilitate bus
wiring;thereisnointernalconnectiontootherXNXcircuitry.
Terminal 3-1 is connected internally to 3-2. Similarly, terminal 3-3
is connected internally to 3-4.
+
+
TB-3 Modbus
Use shorting jumper
supplied to maintain
connection during
service
S5 Sim Mode
Out
In
3-1
3-2
3-3
3-4
3-5
3-6
F+
F+
F-
F-
FS
FS
TB-3 FFB
Jumper
assignments
1
2
3
4
5
6
to internal
ground lug
SW5 -
Sim switch
Internal ground lug
Foundation Fieldbus
ground cable
Figure 39. XNX Foundation Fieldbus option board and terminal block
2.2.6 Terminal Block Connections
Connections to the transmitter are made via pluggable terminal
blocks secured to the back of the POD. The terminal blocks are
keyedandpolarized.Acolorcodedlabelassistsinwiringwhen
the block is removed from the POD.
The terminals are suitable for use with 12 to 28 AWG or 0.8 to
2.5mm
2
wire.Wireinsulationmustbestripped5/16”(0.312”)or
8mm. Tighten each terminal to a maximum of 4.5 in-lbs (0.51 Nm).
Uptofourterminalblocksareprovided;eachhaving2,6,9,or10
positions (see the
XNX Quick Start Guide
for additional details).
Two terminal block jumpers are included to provide an electrical
connection without connection to the Personality Board. Install
the jumpers between pins 1 and 2 and between pins 3 and 4 to
support multi-node wiring.
Warning: When the transmitter is equipped with the optional Remote Mount
Kit, the remote sensor must be securely mounted in a fixed position. The Remote
Sensor kit is not intednded to be used as a hand-held sensor.