User's Instructions
4
attenuation will be adversely effected by anything that impairs the seal of the earmuff
cushions against the head, such as thick spectacle frames, headdress, balaclavas, etc.
IMPORTANT USER INFORMATION
1 The earmuffs should be fitted, adjusted and maintained in accordance with the
instructions.
2 The earmuffs should be worn at all times in noisy surroundings
3 The earmuffs should be regularly inspected for serviceability.
4 The earmuffs can be cleaned with soap and warm water. They should not be dipped
into water.
5 Earmuffs and, in particular, cushions may deteriorate with use and should be
examined at frequent intervals for cracking and leakage. To replace ear cushions,
pull off the old ones and snap the new ones into place. To order new ear cushions,
please see hygiene kit information.
6 The fitting of hygiene covers to the cushions may affect the acoustic performance
of the earmuffs.
7 Before and after use, store in a dry, cool place. The temperature should not exceed
+50
°
C.
8 This product may be adversely affected by certain chemical substances. Further
information should be sought from the manufacturer.
9 All Honeywell thermoplastic hearing protection products will remain in good
condition with regard to shelf life while the product is stored in a warehouse under
controlled conditions.
For Earmuffs: Humidity less than 80%, Temperature 0
°
C to 50
°
C.
(C) OPERATING THE HEADSET GETTING STARTED
GETTING STARTED
Power On/Off Hold *C1 for 2s Audio Tone
Adjust hear-through
volume
Rotate dial *C5 Volume increase /decrease
DOSE MONITORING
Dose safe (0-85%) *C3 blinks green
Dose warning (85%-100%) *C3 blinks orange + Warning tone
Dose Alarm (Above 100%) *C3 blinks red + Warning tone
Reset Dose Hold *C2 for 5s
On success, *C3 double flashes green + audio
tone
HEADSET CONTROLS
C1 Power Button C5 Hear-Through Volume
C2 Dose Button C6 Battery latch
C3 Dose Status Indicator C7 Battery lid
C4 System Status Indicator C8 Microphone Covers