Removable Duct Collars
Spend less time on the ladder by easily connecting the duct-
worktothecollarsawayfromtheunitbeforeit’shung,and
thenslidingthecollarsbackintoplaceonceducted.
Intuitive Balancing
Twovariable-speedmotors—oneforeachairstream—work
with the integrated speed control so installers can adjust the
speed of each motor up and down to easily balance the sys-
tem. This eliminates the need for adjusting dampers.
Adjustable Hanging Straps
Justliketighteningorlooseningstrapsonabackpack,these
strapsmakeiteasytoraise,lowerandleveltheunitintoplace.
Ventilation Performance VNT5200E
External Static Pressure Net Supply Air Flow
Pa in w.c. L/s CFM
25 0.1 98 208
50 0.2 94 200
75 0.3 87 186
100 0.4 82 175
125 0.5 74 157
150 0.6 65 138
175 0.7 60 127
200 0.8 53 112
225 0.9 44 94
250 1.0 38 81
VNT5200E1000
AIR FLOW (L/S)
0
0.2
0.4
0.6
0.8
1
1.2
050 100 150 200 250
0
25
50
75
100
125
150
175
200
225
250
275
300
0102030405060708090100 110
NET SUPPLY AIR FLOW
AIR FLOW (CFM)
EXTERNAL
STATIC
PRESSURE
(IN. W. C)
EXTERNAL
STATIC
PRESSURE
(PA)
M32357
Push Through—Operation System
Outside air is pushed through the heat exchanger, which acts
as a noise reducer. This process is very silent and provides
you with better home comfort.
FRESH AIR
FROM
OUTSIDE
FRESH AIR
FROM
OUTSIDE
EXHAUST
AIR TO
OUTSIDE
EXHAUST
AIR FROM
HOME
M32359
Proportional Defrost—Operation System
The defrost energy is controlled by the outdoor air tempera-
ture. The motor speed essentially increases as outdoor tem-
perature drops to provide increased defrost capability.
WARNING: Installation must be performed by a
qualified service technician and must comply with
local codes. Remove power to the device before
installing or servicing the device. Failure to connect
the device according to these instructions may
result in damage to the device or the controls.
Energy Performance VNT5200E
Supply Temperature Net Supply Air Flow Average Power Sensible Recovery Apparent Sensible
°C °F L/s CFM Watts Efficiency (%) Effectiveness (%)
Heating
0 32 35 74 75 58 69
0 32 50 106 100 51 66
0 32 70 149 126 44 64
-15 5 35 74 80 58 69
35 95 35 74 75 53