Datasheet
2 sensing.honeywell.com
BASIC SWITCH FOR HAZARDOUS LOCATIONS, V15W2 SERIES
TABLE 1. SPECIFICATIONS
CHARACTERISTIC PARAMETER
Circuitry SPDT, SPNO, SPNC
Operating force 100 gf, 200 gf
Termination quick connect: 4,8 mm x 0,5 mm
Actuators
pin plunger, roller plunger
other actuators/levers available for special order
Agency certification UL, cUL, ENEC, CQC, ATEX, IEC Ex
Sealing IP67 equivalent (terminals are sealed, but they are exposed so official rating is IP00)
Operating temperature 25 °C to 85 °C [13 °F to 185 °F]
Mechanical life (cycles) 1,000,000 cycles min. @ 60 cycles/minute max.
Dielectric strength 1000 Vac (RMS) for one minute between open contacts, leakage current <10 mA
Switch resistance (initial) 50 mOhm max.
Insulation resistance 100 mOhm min. (500 Vdc for one minute)
Contact material Silver alloy
Housing material PBT thermoplastic polyester
Sealing material Silicone
TABLE 2. ELECTRICAL RATINGS
CHARACTERISTIC PARAMETER
UL/cUL electrical rating per UL 610581 5 A, 1/10 HP @ 125 Vac/250 Vac, 10,000 cycles
ENEC/CQC electrical rating per IEC 610581 and GB15091.1 5 A, 125 Vac/250 Vac, 50,000 cycles
TABLE 3. HAZARDOUS AREA CERTIFICATION
ATEX and IEC Ex per EN/IEC 600790 and EN/IEC 6007915
Ex nC IIA T5 Gc
25°C < Tamb < +85°C
FIGURE 1. PRODUCT NOMENCLATURE
Not all combinations of model code are available.
Please contact your Honeywell provider/representative for assistance.
1
These options have a three-month lead time for set up.
V15W2
Switch Type
A
Lever
Location
A
No lever
Lever pivot
far from
plunger
02
Lever
Type
Contact
Material
MICRO SWITCH
Hazardous
Location-Rated
V15W2 Basic
Switch
Pin plunger
E
Terminals
Z
Circuitry
E
Quick connect
4,8 mm x 0,5 mm
Z
SPDT
200
200
100
100 g max.
200 g
max.
K
Metric
(Ø 3,1 mm)
Mounting
Holes
USA
(Ø 2,9 mm)
Operating
Force
—
Standard
silver alloy
C
P
SPNO
SPNC
B
Lever pivot
near plunger
01
02
03
Short straight
lever
Standard
straight lever
Long straight
lever
1
04
05
06
Simulated
roller lever
1
Roller lever
Long roller
lever
1
W2
Electrical Rating
(must be included)
A
Gold-plated
silver alloy
— A
5 A, 1/10 HP
125 Vac/250 Vac
W2
Special
Designator
A special designator
code is used to
indicate some
non-standard feature
such as a special
actuator, wire color,
wire length, connecto
r,
etc. Review product
specification to
determine the nature
of the non-standard
feature. This code
will consist of up to
three alphanumeric
characters. A blank
designates no
difference from
standard listing.