Manual
Table Of Contents

T10 PRO SMART THERMOSTAT WITH REDLINK
33-00462—01 22
3240 Minimum
Compressor Off
Time
Off, 1-5 minutes 5 The thermostat has a built in compressor
protection (minimum off timer) that
prevents the compressor from restarting too
early after a shutdown. The minimum-off
timer is activated after the compressor turns
off. If there is a call during the minimum-off
timer, the thermostat shows “waiting for
equipment” in the display.
3260 Extended fan
run time in cool
0, 30, 60, 90 seconds,
2, 3, 4, 5, 6, 7, 8, 9, 10,
11, 12, 13, 14, 15
minutes
0 seconds After the call for cooling ends, the
thermostat keeps the fan on for the selected
amount of time for increased efficiency. This
may reintroduce humidity into the living
space.
3260 Extended fan
run time in heat
0, 30, 60, 90 seconds,
2, 3, 4, 5, 6, 7, 8, 9, 10,
11, 12, 13, 14, 15
minutes
0 seconds After the call for heating ends, the
thermostat keeps the fan on for the selected
amount of time for increased efficiency.
4090 Adaptive
Intelligent
Recovery
• No
• Yes
Yes No:
The system will begin heating or cooling
recovery at the scheduled time.
Yes:
The thermostat will begin heating or cooling
recovery early to ensure that the
temperature is reached at the scheduled
time. The thermostat will adjust the start
time of the equipment based on how quickly
the scheduled temperature was reached on
previous days.
4100 Minimum Cool
Setpoint
50° F to 99° F *
10.0° C to 36.5° C
50° F
(10° C)
The user cannot set the cool setpoint below
this level. Thermostat needs to be
configured for at least 1 cool/compressor
stage.
* The minimum cool setpoint cannot be set
higher than the maximum cool setpoint. If
these settings are the same, the cool
setpoint is not adjustable from homescreen.
4100 Maximum Cool
Setpoint
50° F to 99° F *
31° C to 37° C
90° F
(32° C)
The user cannot set the cool setpoint above
this level. Thermostat needs to be
configured for at least 1 cool/compressor
stage.
* The maximum cool setpoint cannot be set
lower than the minimum cool setpoint.
If the max cool and min cool settings are the
same, the cool setpoint is not adjustable
from homescreen.
4100 Minimum Heat
Setpoint
40° F to 90° F *
4.5° C to 32° C
50° F
(10° C)
The user cannot set the Heat setpoint below
this level. Thermostat needs to be
configured for at least 1 heat stage.
* The minimum heat setpoint cannot be set
higher than the maximum heat setpoint or
the minimum cool.
If these settings are the same, the heat
setpoint is not adjustable from homescreen.
4100 Maximum Heat
Setpoint
40° F to 90° F *
4.5° C to 32° C
90° F
(32° C)
The user cannot set the Heat setpoint above
this level. Thermostat needs to be
configured for at least 1 heat stage.
* The maximum heat setpoint cannot be set
lower than the minimum heat setpoint.
If these settings are the same, the heat
setpoint is not adjustable from homescreen.
Table 5. Installer Setup (ISU)
ISU #
Installer Setup
Name Settings Default Notes