Table 5. Installer Setup (ISU)
ISU #
Installer Setup
Name Settings Default Notes
None Language English
Francais
Espanol
Engligh
None Room Bedroom
Living space
Other
No defaulted
value
In what type of room will this thermostat be
installed?
These questions are asked for two reasons:
1. Other RedLINK indoor sensors could
be used for other spaces in the home.
When these sensors are used, the cus-
tomer is able to select certain sensors
to have priority under certain condi-
tions (active rooms based on motion
detection, selected rooms based on
schedule settings).
2. There may be multiple thermostats in
the same location controlled via the
app.
None Room Bedroom:
Guest Bedroom
Master Bedroom
Add room
Living Space:
Family room
Living Room
Rec Room
Add room
Other:
Dining Room
Kitchen
Basement
Hallway
Add room
None Units Fahrenheit
Celsius
Fahrenheit Which temperature scale would you like to
use?
None RedLINK
Devices
Add device
Set up later
Use to connect RedLINK wireless
Accessories.
List of compatible RedLINK accessories
shown on page 4. Thermostat display will
guide you through linking RedLINK
accessories to thermostat.
None Outdoor
temperature
None
Wired
Internet
None Outdoor temperature is used for balance
point lockout, aux heat lockout, frost control,
high and low outdoor temperature lockouts
for ventilation
2000 System Type Conventional
Forced Air Heat
Heat Pump
Radiant Heat
None (cool only)
Conventional
Forced Air Heat
2010 Equipment
Type
Conventional Forced
Air Heat
Standard Efficiency
Gas Forced Air
High Efficiency Gas
forced air
Oil Forced Air
Electric Forced Air
Hot water Fan Coil
Heat Pump
Air to Air
Geothermal
Radiant Heat
Hot Water Radiant
Heat
Steam
None (cool only)
This ISU is not displayed when ISU 2000
Heating System Type is set to None (Cool
Only).
Available options depend on “System Type”
setting
Cycle Rate and Fan Operation automatically
default to the correct settings based on the
equipment type selected.
2060 Reversing Valve O (O/B on Cool)
B (O/B on Heat
O (O/B on Cool) Only displayed if the system type (ISU 2000)
is set to Heat Pump