Manual
Table Of Contents

T10 PRO SMART THERMOSTAT WITH REDLINK
15 33-00462—01
1. 1. Remove the cover from the remote sensor see Fig.
35.
Fig. 35. Remove the cover
2. Pull wires through wire hole.
3. Position wallplate on wall, level and mark screw hole
positions with pencil.
4. Drill holes at marked positions, then tap in supplied
wall anchors.
5. Place wallplate over anchors, insert and tighten
mounting screws see Fig. 36.
Fig. 36. Mount wallplate to wall
6. Replace the cover on the remote sensor.
CAUTION
Electrical Shock Hazard.
Can cause electrical shock or equipment
damage.
Disconnect power supply before connecting wiring.
Wiring 1 C7189U1005 sensors (10k ohm) for temperature
control. Select 10K in the Installer Setup (ISU 5030) when
using C7189U1005 sensor(s).
Fig. 37. Wiring 1 C7189I sensor.
Wiring 4 C7189U1005 sensors (10k ohm) for temperature
averaging network. Select 10K in the Installer Setup (ISU
5030) when using C7189U1005 sensor(s).
Fig. 38. Wiring 4 C7189U sensors.
Installing Wired outdoor sensor
See ISU setting “outdoor temperature” on page 17 for
correct thermostat configuration.
Follow instructions included with C7089U1006 wired
outdoor sensor.
Location and Mounting (Fig. 39)
Mount the sensor where:
• cannot tamper with settings.
• there is good air circulation.
• it can measure true outdoor ambient temperature.
• surface is flat.
• wire distance between C7089U and thermostat is less
than 200 feet.
Do not mount the sensor:
• in direct sunlight.
• where hot or cold air blows on the sensor. Discharge
line from an outdoor compressor unit, vent or fan
causes inaccurate temperature readings.
• where snow, ice or debris can cover it.
Use the following steps to mount the sensor:
1. Remove the sensor from the mounting clip.
2. Mark the area on the location selected for mounting
the sensor mounting clip.
3. Mount the clip.
M24056A
UP
M24057A
UP
UWP
M37794
S
S
C7189
S
S
C7189 C7189
C7189 C7189
UWP
M37795
THE NUMBER OF C7189U SENSORS MUST BE
A SQUARE NUMBER (1, 4, 9, 16, ETC.)