VisionPRO 8000 Spec Sheet 2017
Table Of Contents
- Application
- Features
- Contents
- Specifications
- System Installation
- Installation Options
- Guidelines for Installing RedLINK Devices
- Installing Equipment Interface Module (if used)
- Wiring 24 Vac Common
- Selecting Discharge and Return Air Temperature Sensor Mounting Locations
- Installing Discharge and Return Air Temperature Sensors
- Selecting Thermostat Location
- Installing Wallplate
- Installing VisionPRO® 8000 with RedLINK™
- Wiring the Thermostat
- Remove Coin Cell Battery Tab
- Mounting Thermostat on Wallplate
- Power Optional RedLINK™ Accessories
- Performing Initial Setup
- Installer Tests
- Operation
- Setting the Time/Date
- Setting the Fan
- Setting System Mode
- Adjusting Program Schedules
- Overriding Schedules: Residential Use
- Overriding Schedules: Commercial Use
- Viewing Equipment Status
- Setting Vacation Hold: Residential Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Remote Setback: Commercial Use
- Adjusting Humidification Settings
- Adjusting Dehumidification Settings: Residential Use
- Adjusting Dehumidification Settings: Commercial Use
- Adjusting Ventilation Settings
- Ventilation Options
- Setting Preferences
- Cleaning the Thermostat Screen
- Adjusting Security Settings
- Viewing Dealer Information
- Advanced Features
- Installer Options
- Using the Temperature Display
- Using the Humidity Display
- Universal Outputs (U1, U2, U3)
- Universal Inputs (S1, S2, S3, S4)
- Data Logs
- Dry Contact Alerts
- Set Up the Dry Contact Alerts
- Staging Control
- Heat Pump and Backup Heat Operation
- Indoor Air Quality (IAQ) Control
- IAQ Reminders
- Customizable Reminders
- MicroSD card
- Commercial Features
- Overriding Schedules: Commercial Use
- Setting Holiday/Event Schedules: Commercial Use
- Setting Custom Events: Commercial Use
- Setting Holiday Schedule: Commercial Use
- Setting Holiday Override: Commercial Use
- Initiating Occupancy Mode: Commercial Use
- Ramp Rates (Commercial Use)
- Remote Setback (Commercial Use)
- Economizer and Time of Day (TOD) Operation
- Pre-Occupancy Purge
- Battery Replacement
- Optional Accessories
- Portable Comfort Control
- Remote Indoor Sensors
- Replacing a Thermostat
- Replacing an Equipment Interface Module
- Wiring
- Zoning
- Troubleshooting
- Regulatory Information
VISIONPRO
®
8000 WITH REDLINK™
68-0312—05 96
When ISU 1012 Ventilation Priority is set to Lockouts are Pri-
ority, or ISU 1005 Ventilation Control Methods is set to Per-
cent On Time, the thermostat will indicate whether this meets
or may not meet the ASHRAE 62.2 Standard or the Percent
On Time setting. See Fig. 235.
Fig. 235.
When ISU 1012 Ventilation Priority is set to ASHRAE is Pri-
ority, the screen below will indicate the maximum length of
time that ventilation can be locked out over a 21 hour time
period. For example, Ventilation Lockout Will Not Exceed
12.5 hours. The length of time that ventilation is locked out is
limited to ensure that the ASHRAE 62.2 Ventilation Standard
is met. See Fig. 236.
Fig. 236.
10. Select whether to lockout ventilation on humidifica-
tion or dehumidification calls. This feature is used to
help reach the user's desired humidity level by not
allowing the ventilation equipment to run during a
call for humidification or dehumidification. The ther-
mostat will indicate whether this meets or may not
meet the ASHRAE 62.2 Standard or the Percent On
Time setting. See Fig. 237.
NOTE: ISU 1014 Lockout Ventilation on Humidifi-
cation or Dehumidification Calls is not an
option when you select ASHRAE is Priority at
ISU 1012.
Fig. 237.
11. Select whether to Ventilate on High Indoor Humidity.
See “Ventilate on High Indoor Humidity (ISU 1016)”
on page 93 for more information. See Fig. 238.
Fig. 238.
Control Ventilation Level
1. Touch MENU, and select Ventilation.
Fig. 239.
Fig. 240.
Scroll to see:
May not meet
ASHRAE 62.2 due to
the ventilation
Scroll to see:
Ventilation
lockout will not
exceed
MCR34100
MCR34132
Ventilation
Equipment Status