VisionPRO 8000 Spec Sheet 2017

Table Of Contents
VISIONPRO
®
8000 WITH REDLINK™
68-0312—05 20
Fig. 54.
NOTE: If you link more than 1 wireless indoor sen-
sor, and forget to name them, you will be
prompted to name each wireless indoor sen-
sor after you exit wireless setup. See Fig. 55.
Fig. 55.
Entry/Exit Remote or Vent Boost Remote
1. Press and quickly release the CONNECT button.
Fig. 56. Connect button and status light on Entry/Exit
Remote or Vent Boost Remote.
2. After a short delay, the status light will glow green for
15 seconds. If the status light turns red, the remote
did not link with the thermostat for the connection
process.
NOTE: The thermostat can work with up to 3 Entry/Exit
remotes. Each Entry/Exit remote can control up to
16 thermostats.
NOTE: The thermostat can work with up to 6 Vent Boost
remotes.
Finding Your Password (Date Code)
to Access Installer Options
You need a password (Date Code) to access Installer
Options. Installer Options allow you to:
Make changes to the Installer Setup.
Perform an Installer Test.
Add, remove, rename or view connected RedLINK
accessories.
Reset the thermostat to Factory Default settings.
The password (Date Code) is located on the back of the
thermostat. It can also be found by following these steps:
1. Touch Menu.
2. Select Dealer Information.
Fig. 57.
3. Scroll down to see the Date Code.
Fig. 58.
MCR33096
MCR34022
Dealer Information
Installer Options
MCR33975
TH8321R1001
Date Code: 1324