Table 1. Operating Characteristics (over operating voltage and temperature, unless otherwise noted)
Characteristic
Min.
Typ.
Max.
Note
Supply voltage
3.8 Vdc
30 Vdc
Current consumption
10 mA
Supply current (operated at 25 °C, Vs = 5 V)
6.5 mA
Output voltage (operated)
0.40 Vdc
sinking, 20 mA max.
Output current (operated)
20 mA
Output leakage current (released)
10 A
Output switching time:
rise, 10% to 90%
fall, 90% to 10%
0.05 s
0.15 s
1.5 s
1.5 s
V
CC
= 12 V,
RL = 1.6 k ,
CL = 20 pF
Table 2. Output Current Absolute Limits
Supply Voltage
Output Current
-1 Vdc to 24 Vdc
50 mA max.
24 Vdc to 25 Vdc
37 mA max.
25 Vdc to 26 Vdc
33 mA max.
26 Vdc to 27 Vdc
28 mA max.
27 Vdc to 28 Vdc
24 mA max.
28 Vdc to 29 Vdc
19 mA max.
29 Vdc to 30 Vdc
15 mA max.
Table 3. Absolute Maximum Ratings
Characteristic
Parameter
Supply voltage
-1 Vdc to +30 Vdc
Voltage externally applied to output
+30 Vdc max. (OFF only)
-0.5 Vdc min. (OFF or ON)
Output ON current
see Table 2
Operating temperature
-40 °C to 150 °C [-40 °F to 302 °F]
Storage temperature
-50 °C to 150 °C [-58 °F to 302 F]
Magnetic flux
no limit; circuit cannot be damaged by magnetic overdrive
NOTICE
Absolute maximum ratings are the extreme limits that the
device will withstand without damage to the device. However,
the electrical and mechanical characteristics are not
guaranteed as the maximum limits (above recommended
operating conditions) are approached, nor will the device
necessarily operate at absolute maximum ratings.
ELECTROSTATIC
SENSITIVE
DEVICES
DO NOT OPEN OR HANDLE
EXCEPT AT A
STATIC FREE WORKSTATION
ESD SENSITIVITY:
CLASS 3
CAUTION