Instruction Manual
System Capacity
• Annunciators ...................................................................... 2
Electrical Specifications
• SFP-5UDC (FLPS-7 Power Supply): 120 VAC, 50/60 HZ,
3.90 A
• SFP-10UDC (FLPS-7 Power Supply): 120 VAC, 50/60 HZ,
3.90 A
•
Wire size:
minimum 14 AWG (2.0 mm
2
) with 600 V insula-
tion, supervised, nonpower-limited
•
Battery size
: minimum 12 AH; maximum 18 AH.
Cabinet Specifications
Door: 48.92 cm. (19.26") high x 42.73 cm. (16.82") wide x 1.82
cm. (0.72") deep. Backbox: 48.26 cm. (19.00") high x 42.29
cm. (16.65") wide x 13.34 cm. (5.25") deep. Trim Ring (TR-
CE-B): 55.88 cm. (22.00") high x 49.91 cm. (19.65") wide.
Shipping Specifications
Dimensions:
– 50.80 cm (20.00") high
– 57.15 cm (22.5") wide
– 21.59 cm (8.5") deep.
Weight: 12.20 kg (27 lb )
Temperature and Humidity Ranges
This system meets NFPA requirements for operation at 0 –
49°C and at a relative humidity 93% ± 2% RH (noncondens-
ing) at 32°C ± 2°C. However, the useful life of the system's
standby batteries and the electronic components may be
adversely affected by extreme temperature ranges and humid-
ity. Therefore, it is recommended that this system and its
peripherals be installed in an environment with a normal room
temperature of 15 – 27°C.
Agency Listings and Approvals
The listings and approvals below apply to the basic SFP-5UDC
and SFP-10UDC control panels. In some cases, certain mod-
ules or applications may not be listed by certain approval
agencies, or listing may be in process. Consult factory for lat-
est listing status.
• UL/ULC Listed: File S635
• FM Approved
• CSFM: 7165-0028:0246
NOTE: For additional UL-listed models, see DN-60185.
NFPA Standards
The SFP-5UDC/SFP-10UDC complies with the following NFPA
72 Fire Alarm Systems requirements:
– LOCAL (Automatic, Manual, Waterflow and Sprinkler
Supervisory).
–AUXILIARY (Automatic, Manual and Waterflow) (requires
4XTM).
– REMOTE STATION (Automatic, Manual and Waterflow)
(Where a DACT is not accepted, the alarm, trouble and
supervisory relays may be connected to UL 864 listed
transmitters. For reverse polarity signaling of alarm and
trouble, 4XTM is required.)
–PROPRIETARY (Automatic, Manual and Waterflow).
– CENTRAL STATION (Automatic, Manual and Waterflow,
and Sprinkler Supervised).
NOTIFIER® and System Sensor® are registered trademarks of Honeywell
International Inc.
©2010 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
Page 4 of 4 — Canadian DN-60437:C • 07/26/2010
This document is not intended to be used for
installation purposes. We try to keep our
product information up-to-date and accurate.
We cannot cover all specific applications or
anticipate all requirements. All specifications are
subject to change without notice.