Use and Care Manual
18 19
Equipment Setup Options
Option # Option Name Option Value (factory default in bold)
120 Schedule Type No Schedule
MOSU = Every day the same
MOFR SA SU = 511 schedule
MO-FR SA-SU = 5-2 schedule
Each Day = Every day different
Note: You can change default MOFR, SASU schedule here. To edit periods during days,
temperature setpoints, or to turn Schedule On/Off, touch MENU and go to SCHEDULE.
200 System Type Conventional Forced Air, Heat Pump, Boiler, Cool Only
Note: This option selects the basic system type your thermostat will control.
205 Equipment Type
Conventional Forced Air Heat:
Standard Gas, High Efficiency Gas, Oil, Electric, Hot Water Fan Coil
Heat Pump:
Air to Air, Geothermal
Radiant Heat:
Hot Water, Fan Coil, Steam
Note: This option selects the equipment type your thermostat will control. Note: This
feature is NOT displayed if feature 200 is set to Cool Only.
218 Reversing Valve O/B on Cool, 0/B on Heat
Note: This option is only displayed if the Heat Pump configured. Select whether reversing
valve O/B should energize in cool or in heat.
220 Cool Stages /
Compressor Stages
#200=Conventional/
200=Heat Pump
0, 1, 2
Note: Select how many Cool or Compressor stages of your equipment the thermostat will
control. Maximum of 2 Cool/Compressor Stages.
221 Heat Stages,
Aux/E Stages
#200=Conventional/
200=Heat Pump
Heat Stages: 0, 1, 2
Aux/E stages: 0, 1
Note: Select how many Heat or Aux/E stages of your equipment the thermostat will
control. Maximum of 2 Heat Stages for conventional systems. Maximum of 1 Aux/E stage
for systems with more than 1 heating equipment type.