How to Guide

WHEN INSTALLING THIS PRODUCT...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous
condition.
2. Check the ratings given in these instructions and on
the product to ensure the product is suitable for your
application.
3. Ensure the installer is a trained, experienced service
technician.
4. After completing installation, use these instructions
3. Mount the R8184M to the junction box. Refer to
to check product operation.
Fig. 4.
CHOOSE LOCATlON
MAKE WlRlNG CONNECTlONS AND MOUNT
R8184M
1. Ensure all wiring complies with local codes and
ordinances.
2. Make line voltage connections as shown in Fig. 3.
l Splice leads with solderless connectors.
l Do not exceed load ratings shown on device label or
in the Specifications, page 2.
l Leave enough slack in the wires to permit easy
access into the junction box.
4. Connect the C554A Cadmium Sulfide Cell (ordered
seoaratelv) leadwires to the F-F terminals on the terminal
‘.’ :. ..‘.’ ‘.
rNsTALt*T,ON::‘
..‘..:; ‘,..‘:‘.‘~,~..‘.“;..’ :
l Mount the R8184M on a 4 x 4 inch junction box,
strip, -
directlyontheburnerhousing,orinsidetheappliance
cabinet.
5. Connect all remaining lowvoftage wiring connections
l In replacement applications, mount the R8184M in as shown in Fig. 3.
the same location as the old control.
9 Make all line voltage connections in a wiring enclo-
sure such as a junction box or the appliance wiring NOTE: Y and G terminals are provided to simplify cpnnec-
compartment. tions of cooling equipment; they are not connected to
l Ensure operating temperatures at the selected loca- the internal circuitry of the R8184M.
tion are between -40°F and 130°F [-4O”C and 54%].
THERMOSTAT
WIMI
R8104M PROTECTORELAY
CONTROL I
Ir
-CAPACITOR
I
BLACK
L I
A USED FOR 4 AMP THERMOSTAT ONLY.
Ll
(HOT)
FIG. 3--WIRING DIAGRAM OF R8184M WlTH LOCKOUT INDICATOR LIGHT.
4