How to Guide
THE R8184M PROTECTORELAY OIL BURNER CON-
TROLOPERATES THE OIL BURNER AND OIL VALVE
(IF DESIRED) IN RESPONSE TO A CALL FOR HEAT
FROM A LOW VOLTAGE CONTROL CIRCUIT.
0 Provides intermittent ignition.
0 Used with a C564A Cadmium Sulfide Cell and 24 Vat
thermostat.
Cl Integral 24 Vat transformer powers bw voltage con-
trol circuit.
q Solid state flame sensing circuit.
Cl Enclosed safety switch with external red reset button.
Safety switch must be manually reset after safety shut-
down.
0 45 second safety switch timing.
0 Exposed terminal strip with screw terminals for low
voltage connections. Y and G terminals are tie points for
cooling circuit connections.
0 Color-coded leadwires for line voltage connections.
0 Mounts in any position on a standard 4 x 4 inch
junction box or directly on burner housing.