Submittal Sheet
Table Of Contents
Q624A SOLID STATE SPARK GENERATOR
60-2049—7 2
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
Mounting: Surface.
Dimensions: See Fig. 1.
Weight: 3 lb. (1.4 kg).
Approvals:
Underwriters Laboratories Inc. Component Recognized: File
No. MH7453, Guide No. JHYR2; tested and accepted for
use in ambient temperatures ranging from -40°F to + 125°F
(-40°C to +52°C).
Canadian Standards Association Certified: File No. LR1620.
American Gas Association Design Certified: Certificate No.
G-140.401.
Accessories:
C7005 Gas Pilot, with ignition electrode.
Q179 Gas Pilot, with ignition electrode.
134666 Insulator; may be used to cover terminal, to prevent
contamination, and to give added terminal protection.
32004766-001 24 in. (610 mm) Ignition Cable Assembly.
32004766-002 120 in. (3.05 m) Ignition Cable Assembly.
32004766-003 Ignition Cable (per foot, specify required
length).
32004766-004 60 in. (1.52 m) Ignition Cable Assembly.
Cable should be rated for 25kV at 482°F (250°C).
Fig. 1. Q624A Solid State Spark Generator dimensions in in. (mm).
INSTALLATION
When Installing This Product…
1. Read these instructions carefully. Failure to follow them
could damage the product or cause a hazardous
condition.
2. Check the ratings given in the instructions and on the
product to make sure the product is suitable for your
application.
3. Installer must be a trained, experienced, flame
safeguard control technician.
4. After installation is complete, check out product
operation as provided in these instructions.
TERMINAL
BOARD
MOUNTING
PLATE
HIGH VOLTAGE
ELECTRODE
COVER SCREW
KNOCKOUT FOR
1/2 INCH CONDUIT
1-1/4
(32)
13/16
(20.5)
5-1/4 (133.5)
1
9/64
(7)
4-1/4
(108)
1-1/4
(32)
3 (76)
M20858
5-15/16 (151)
6-3/4 (171.5)