Datasheet

Sensing and Internet of Things 3
MICRO SWITCH Compact Limit Switches, NGC Series
Table 2. Electrical Rating and Utilization Category
SPDT 1NO/1NC DPDT 2NO/2NC SPDT and DPDT
ac dc ac dc gold-plated contacts
A300 Ue
(volts)
AC15 Ie
(amps)
Q300 Ue
(volts)
DC13 Ie
(amps)
C300 Ue
(volts)
AC15 Ie
(amps)
R300 Ue
(volts
DC13 Ie
(amps)
30 mVdc
10 mA resistive
120 6 125 0.55 240 0.75 250 0.1
240 3 250 0.27
Per IEC 6094751 and UL 508
Figure 1. Product Nomenclature and Order Guide
2
6
1
None
Standard,
fixed length
1
Adjustable
length,
roller lever
1
Short,
fixed length
1
NGC
Switch Type
Head Type
C
B
A
Side rotary
Roller
plunger
NGC Series
Medium-Dut
y
Compact
Limit Switch
24
07
01
1NC/1NO
snap action
silver contacts
32
01
Switch Type
M
Pin plunger w/
boot seal
NOTE: not all combinations
of model code are available.
Please contact your Honeywell
provider/representative for assistance.
1
Only applicable for head type “A
2
Only applicable for lever types “1, 2, 6” and switch types “01” and “07”
3
Only applicable for lever types “2, 6”
4
Only applicable for metal housing Type “M”
5
Typically applicable for plastic housing Type “P” and “Q”, and without grounding metal housing Type “M”
6
Only applicable for switch type “01” and “07”
7
Cable meets EN 50306, but does not meet with UL requirement
8
Only applicable for “O0” cable length. Not applicable to switch types “24” and “32”
9
“00” cable length is not applicable for connector/cable exit type “A”, “B”, “D”, and “R”. Not applicable to switch types “24” and “32”
10
DIN 551022009 does not apply to NGC variant with suffix modification code “H85”. Also applicable only for connector/cable types “B”, “R”, “N”, and “P”. See table 3
11
Modification code “L40” is a 40 °C variant. Only applicable to connector/cable types “B”, “R”, “N”, and “P”. See table 3
Q
L
Cross roller
plunger
Panel-mount
cross-roller
plunger
P
Panel-mount
roller plunger
R
Panel-mount
pin plunger w/
boot seal
N
Panel-mount
pin plunger
C
B
A
Side exit,
right
Bottom
exit
Side exit,
left
A
Connection
05
02
00
No cable.
Internal
connector
0,25 m
[0.82 ft]
0,5 m
[1.64 ft]
02
Cable Length
10
07
0,7 m
[2.3 ft]
1,0 m
[3.28 ft]
20
15
1,5 m
[4.92 ft]
2,0 m
[6.56 ft]
30
3,0 m
[9.84 ft]
4,0 m
[13.12 ft]
50
5,0 m
[16.4 ft]
40
Connector/Cable
Exiting Housing
D
B
A
Standard cable
Halogen-free
cable
N
M12 4-pin
micro change,
dc connector
5,6,8
PUR cable
P
M12 5-pin
micro change,
dc connector
4,6,8
A
1NC/1NO
snap action
gold contacts
2NC/2NO
snap action
silver contacts
2NC/2NO
snap action
gold contacts
A
Pin plunger
Levers
(Optional)
1
B
C
A
None
18 mm nylon
roller
2
18 mm
stainless steel
roller
2
18 mm nylon
roller, reversed
3
Rollers
(Optional)
1 –
D
18 mm
stainless steel
roller, reversed
3
Modifications
Q
P
M
Metal
Plastic
Plastic with
mounting
ring support
M
Housing
X
None
X
Connector at
End of Cable
D
Long pin
plunger
T
Long
cross-roller
plunger
S
Long roller
plunger
J
Top roller
lever arm
M02
M01
Side rotary
lever,
90° right
Side rotary
lever,
90° left
M08
M07
Side rotary
short lever,
45° right
Side rotary
short lever,
45° left
R
Railway cable
7
L40
H85
High temp
variant,
85 °C
10
Low temp
variant,
-40 °C
11
Table 3. Electgrical Life Expectancy at Illustrated Load
Switch Type Voltage Current Life
SPDT (01) silver contact
1
110 Vdc 1A 500,000
DPDT (24) silver contact
1
110 Vdc 1 A 500,000
DPDT (24) silver contact
2
24 Vdc 15 mA 1,500,000
DPDT (32) gold-plated contact
2
30 mVdc 10 mA 50,000
SPDT (07) gold-plated contact
2
30 mVdc 10 mA 50,000
1
15 cycles/minute max. Applicable to NC circuit only. All loads resistive. Life mentioned are min. life.
2
30 cycles/minute max. All loads resistive. Life mentioned are min. life.