Datasheet

3
Sensing and Internet of Things
HEAVY DUTY, MEDIA-ISOLATED PRESSURE TRANSDUCERS, MIP SERIES
FIGURE 1. NOMENCLATURE AND ORDER GUIDE
MIP A N1 X X 010B S AA X
1
Electrical Connector Type
Special
Output Transfer Function
Media Isolated Pressure
MIP
A
1
Contact Honeywell Sales for custom configurations.
2
Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.
Pressure Range
bar
015P
030P
050P
060P
100P
150P
200P
250P
300P
001B
002B
004B
006B
008B
010B
012B
016B
1 bar
2 bar
4 bar
6 bar
8 bar
10 bar
12 bar
16 bar
15 psi
30 ps
i
50 psi
60 psi
100 psi
150 psi
200 psi
250 psi
300 psi
X
Series
AA
020B
025B
035B
040B
046B
050B
055B
060B
20 bar
25 bar
35 bar
40 bar
46 bar
50 bar
55 bar
60 bar
500P
600P
667P
700P
750P
800P
850P
870P
500 psi
600 psi
667 psi
700 psi
750 psi
800 psi
850 psi
870 psi
psi
F1
7/16-20 UNF
1/4 inch 45° Flare
Female Schrader
(SAE J512)
N1
N2
1/4-18 NPT
(ANSI/ASME B1.20.1)
1/8-27 NPT
(ANSI/ASME B1.20.1)
M12 x 1.5
(ISO 6149-3)
G1/4 A-G
(ISO 1179-3)
M1
G1
Pressure
Port Type
G1/4 A-L
(ISO 1179-2)
G2
Metri-Pack 150,
Standard (UL V-0)
For example, MIPAN1XX010BSAAX defines an MIP Series Heavy Duty, Media Isolated Pressure Transducer,
Metri-Pack 150, standard (UL V-0) electrical connector type, 1/4-18 NPT pressure port type, 10 bar pressure
range, sealed gage pressure reference, ratiometric: 5 Vs, 10% to 90% Vs output transfer function
A
Absolute
S
Sealed gage
2
Special
X
X
Special
Pressure Reference
Ratiometric: 5.0 Vs
,
10% to 90% Vs
CAUTION
PRODUCT DAMAGE DUE TO MISUSE
Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating
materials and thread sealants can result in significantly different torque values from one application to the next.)
Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers.
Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals
can compromise ingress protection, leading to short circuits.
Ensure that filters are used upstream of the transducers to keep media flow free of large particulates and condensed moisture.
MIP Series transducers are dead-end devices. Particulate accumulation may clog the port or damage the diaphragm.
Ensure the transducer is installed with the port facing downwards. Any particulates in the system are less likely to enter and
settle within the transducer if it is in this position.
Ensure that the media does not create a residue when dried. Build-up of residue inside the transducer may affect transducer
output
Failure to comply with these instructions may result in product damage.