Datasheet

Sensing and Internet of Things 35
MICRO SWITCH Heavy-Duty Limit Switch, HDLS Series
SPECIAL APPLICATIONS
High Capacity Limit Switch
Features
High dc current ratings
20 A rating at 120 Vac (single pole)
Plug-in or non-plug in
Positive retention lever arm
High resistance to seismic shock
This series has a wide gap contact block
that handles a higher make/break dc
load. In addition, a special lever arm has
a serrated shaft hole and a cap screw
with locking nut for attaching the lever to the rotary shaft.
This assures a firm grip on the operating shaft and positive
retention of the lever adjustment.
The need for precise operation, coupled with challenging
environmental conditions places rigid demands on any
control. Honeywell’s products are intended to satisfy these
demands with its high capacity HDLS, designed to perform
reliably under these conditions.
Listings
LSQ051 Double pole, non-plug-in,
0.75 in conduit
75°
17°

1-2/5-6
3-4/7-8
3-4/7-8
1-2/5-6
LSQ052 Double pole, plug-in, 0.75
in conduit
LSQ053 Single pole, non-plug-in,
0.5 in conduit
75°
17°

1-2
3-4
3-4
1-2
LSQ054 Single pole, plug-in, 0.5 in
conduit
LSZ616 Replacement lever for above listings
Pretravel 17° max.
Diff. travel 8° max.
Overtravel 58° min.
Oper. torque 0,45 Nm [4 in-lb] max.
Action CW and CCW (spring return)
SPDT
Double Break
DPDT
Double Break
Single Pole Double Pole
Voltage Resistive
Load
Inductive
Load
Resistive
Load
Inductive
Load
125 Vdc 2.0 A 1.0 A 1.0 A 0.4 A
250 Vdc 0.7 A 0.4 A 0.4 A 0.2 A
120 Vac 20 A 20 A 10 A 10 A
240 Vac 15 A 15 A 7.5 A 7.5 A
480 Vac 10 A 10 A 5 A 5 A
600 Vac 5 A 5 A 2.5 A 2.5 A
Maximum operating rate - 15 operations per minute.
NOTE: Same polarity each pole.