Datasheet
Sensing and Internet of Things 5
MICRO SWITCH Heavy-Duty Limit Switch, HDLS Series
HDLS Series Electrical Ratings:
10 A Continuous Carry
ac Volts; Pilot Duty: AC15, A600/B600
Electrical
Rating
Circuitry Vac
Amps at 0.35
Power Factor
Make
Amps at 0.35
Power Factor
Break
A*
AC15,
A600
SPDT
DPDT
120 60 6
240 30 3
480 15 1.5
600 12 1.2
B
AC15,
B600
D
120 30 3
240 15 1.5
480 7.5 0.75
600 6 0.60
D Gravity return (Model LSS..) and extra-low torque (Model
LST..)
HDLS Series Electrical Ratings:
dc Volts; Pilot Duty: DC13, R300
Electrical
Rating
Circuitry Vdc
Make & Break
Amps
Inductive
Make & Break
Amps
Resistive
A, B* SPDT
DPDT
125 0.25 0.8
250 0.15 0.4
* For switches with an indicator light, use only at voltage stated
for indicator light.
MICRO SWITCH HDLS limit switches are capable of the follow-
ing low voltage dc loads
Circuitry Vdc
Amps
Inductive
Amps
Resistive
SPDT 24 10 10
DPDT 24 10 10
ASSEMBLY MODIFICATIONS • ROTARY
Momentary action rotary switches can be furnished in other
than the normal assembled conditions. To specify modifica-
tions, add the numbers shown below to the catalog listings.
Modification number suffixes are:
1 Clockwise actuation only
2 Counterclockwise actuation only
3 Shaft to right of switch front
4 Shaft to left of switch front
5 Shaft to back of switch
7 Indicator light wired to NC circuit
For example,
Catalog listing LSA1A23 is an LSA1A switch adjusted for coun-
terclockwise actuation only. The operating shaft is to the right
side of the switch when viewing it from the front (label side).
No lever.
Catalog listing LSA8A7 is an LSA8A switch with the 240 volt
indicator light wired to the NC circuit. No lever.
PLUNGER ASSEMBLY MODIFICATIONS
Add the following modification numbers to the catalog listing
in the plunger switch:
3 Side plunger to right of switch front
4 Side plunger to left of switch front
5 Side plunger to back of switch
6 Roller on top plungers perpendicular to mounting sur-
face
7 Light on indicator versions wired to NC circuit
8 Roller on side plungers in vertical position
For example,
Catalog listing LSF1A3 is an LSF1A switch with the side roller
plunger to the right side.
PLUGIN VS. NONPLUGIN MODELS
Honeywell HDLS limit switches are offered in two styles: non-
plug-in design and plug-in design. With plug-in construction,
the wiring and conduit connection is made to the base recep-
tacle. This feature reduces downtime as the plug-in unit can
be removed and replaced without disconnecting the wiring or
conduit connections to the switch.