Datasheet

Sensing and Internet of Things 3
MICRO SWITCH Heavy-Duty Limit Switch, Stainless Steel (LS2 Series)
Table 2. Electrical Ratings
10 A Thermal (Ith)
ac Volts; Pilot Duty; AC15, A600
Electrical Rating Circuitry Vac Amps at 0.35 PF (make) Amps at 0.35 PF (carry and break)
AC15, A600 SPDT, DPDT
120 60 6
240 30 3
480 15 1.5
600 12 1.2
Table 3. Electrical Ratings
dc Volts; Pilot Duty; DC13, R300
Electrical rating Circuitry Vdc Make & Break Amps Inductive Make & Break Amps Resistive
DC13, R300 SPDT, DPDT
125 0.25 0.8
250 0.15 0.4
Table 4. Electrical Ratings
MICRO SWITCH HDLS LS2 Series limit switches are capable of the following low voltage loads
Circuitry Vdc Amps Inductive Amps Resistive
SPDT 24 10 10
DPDT 24 10 10
Figure 1. Product Nomenclature: Stainless Steel Version
LS2
Switch Type
LS2 Series
Limit Switch
with stainles
s steel
housing,
fluorocarbon
seals,
with or
without
factory wiring
NOTE: Not all combinations of model codes
are available. Please contact your local
Honeywell provider for assistance.
Opt. Factory Wiring
(Requires
0.75-14 NPT conduit)
A
Actuator Heads
(unless noted, all side rotary
heads are CW/CCW)
D
F
M
N
A
Side rotary,
maintained,
CW (reset), CCW (trip)
Side rotary,
momentary
Top roller plunger,
momentary
Side rotary, central
neutral, momentary
(requires 4N contact)
4K
Contact Block &
Termination
3K
4K
4M
4N
4L
3E
1NC/1NO,
gold-plated contacts,
0.5-14 NPT conduit
1NC/1NO,
0.5-14 NPT conduit
1NC/1NO,
0.75-14 NPT conduit
2NC/2NO,
sequential,
0.75-14 NPT conduit
2NC/2NO,
center neutral,
0.75-14 NPT conduit
C
E
H
L
C
Side rotary, sequential,
momentary
(requires 4M contact)
Top pin plunger,
momentary
Side pin plunger,
momentary
Side roller plunger,
momentary
Side rotary,
momentary, low
pretravel & torque
2NC/2NO,
0.75-14 NPT conduit
PC
M
C
5-conductor STOW-A cable,
1,8 m [6.0 ft] for 1NC/1NO
contact block with ground
5-conductor STOOW-A cable,
6,1 m [20.0 ft] for 1NC/1NO
contact block with ground
9-conductor STOW-A cable,
1,8 m [6.0 ft] for 2NC/2NO