Storage at room temperature (approx. 20°C) at approx. 20~60% of the nominal capacity   
(OCV approx. 3.6 - 3.9 V/cell). 
Keep in closed original container. 
8. Exposure controls/personal protection Exposure limit values Exposure limits   
Ingredient 
Risk 
Codes 
Safety 
Description 
Hazard 
Exposure Controls/Personal Protection 
Cobalt oxide 
R22;R43;
R50/53 
S24;S37;S60;S61 
Xn(Harmful) 
N 
(Dangerous for 
the environment) 
0.1 mg/m3 (TWA)   
Manganese 
(VI) oxide 
R20/22 
S25 
Xn(Harmful) 
Airborne Exposure Limits: 
- OSHA Permissible Exposure Limit (PEL): 
  5 mg/m3 Ceiling for manganese compounds 
as Mn 
- ACGIH Threshold Limit Value (TLV): 
  0.2 mg/m3 (TWA) for manganese, elemental 
and inorganic compounds as Mn 
Nickel oxide 
R43,R49,
R53 
S45,S53,S61 
T(Toxic) 
Airborne Exposure Limits: 
For Nickel, Metal and Insoluble Compounds, 
as Ni: 
- OSHA Permissible Exposure Limits (PEL) -   
  1 mg/m3 (TWA). 
  For Nickel, Elemental / Metal: 
- ACGIH Threshold Limit Value (TLV) - 
  1.5 mg/m3 (TWA), A5 - Not suspected as a   
human carcinogen. 
  For Nickel, Insoluble Compounds, as Ni: 
- ACGIH Threshold Limit Value (TLV) -   
  0.2 mg/m3 (TWA), A1 - Confirmed human 
carcinogen   
Carbon 
R36/37/3
8, 
R36/37 
R20, R10 
S22;S24/25 
F(Highly Flammable) 
Xn(Harmful) 
Xi(Irritant) 
Airborne Exposure Limits: 
- OSHA Permissible Exposure Limits (PELs): 
  activated carbon (graphite, synthetic):   
Total particulate = 15 mg/m3   
Aluminium 
foil 
R17,R15,
R36/38, 
R10,R67,
R65,R62,
R51/53, 
R48/20, 
R38,R11, 
S7/8,S43,S26,S62
,S61, S36/37, 
S33,S29,S16,S9 
F(Highly Flammable) 
Xn(Harmful) 
Xi(Irritant) 
Airborne Exposure Limits: 
-OSHA Permissible Exposure Limit (PEL): 
  15 mg/m3 (TWA) total dust and 5 mg/m3 
(TWA) 
  repairable fraction for Aluminum metal as Al 
-ACGIH Threshold Limit Value (TLV): 
  10 mg/m3 (TWA) Aluminum metal dusts   