SDS
SAFETY DATA SHEET
Freon™ 410A (R-410A) Refrigerant
Version
10.5
Revision Date:
10/10/2020
SDS Number:
1336443-00045
Date of last issue: 02/27/2020
Date of first issue: 02/27/2017
5 / 16
perature
Storage period
:
> 10 y
Further information on stor-
age stability
:
The product has an indefinite shelf life when stored properly.
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Ingredients with workplace control parameters
Components
CAS-No.
Value type
(Form of
exposure)
Control parame-
ters / Permissible
concentration
Basis
Pentafluoroethane
354-33-6
TWA
1,000 ppm
US WEEL
Difluoromethane
75-10-5
TWA
1,000 ppm
US WEEL
Engineering measures
:
Ensure adequate ventilation, especially in confined areas.
Minimize workplace exposure concentrations.
Personal protective equipment
Respiratory protection
:
General and local exhaust ventilation is recommended to
maintain vapor exposures below recommended limits. Where
concentrations are above recommended limits or are
unknown, appropriate respiratory protection should be worn.
Follow OSHA respirator regulations (29 CFR 1910.134) and
use NIOSH/MSHA approved respirators. Protection provided
by air purifying respirators against exposure to any hazar-
dous chemical is limited. Use a positive pressure air supplied
respirator if there is any potential for uncontrolled release,
exposure levels are unknown, or any other circumstance
where air purifying respirators may not provide adequate
protection.
Hand protection
Material
:
Low temperature resistant gloves
Remarks
:
Choose gloves to protect hands against chemicals depending
on the concentration specific to place of work. For special
applications, we recommend clarifying the resistance to che-
micals of the aforementioned protective gloves with the glove
manufacturer. Wash hands before breaks and at the end of
workday. Breakthrough time is not determined for the pro-
duct. Change gloves often!
Eye protection
:
Wear the following personal protective equipment:
Chemical resistant goggles must be worn.
Face-shield
Skin and body protection
:
Skin should be washed after contact.
Protective measures
:
Wear cold insulating gloves/ face shield/ eye protection.