SDS
SAFETY DATA SHEET
Freon™ 410A (R-410A) Refrigerant
Version
10.5
Revision Date:
10/10/2020
SDS Number:
1336443-00045
Date of last issue: 02/27/2020
Date of first issue: 02/27/2017
3 / 16
cial caution.
SECTION 5. FIRE-FIGHTING MEASURES
Suitable extinguishing media
:
Not applicable
Will not burn
Unsuitable extinguishing
media
:
Not applicable
Will not burn
Specific hazards during fire
fighting
:
Exposure to combustion products may be a hazard to health.
If the temperature rises there is danger of the vessels bursting
due to the high vapor pressure.
Hazardous combustion prod-
ucts
:
Fluorine compounds
Carbon oxides
Hydrogen fluoride
carbonyl fluoride
Specific extinguishing meth-
ods
:
Use extinguishing measures that are appropriate to local cir-
cumstances and the surrounding environment.
Fight fire remotely due to the risk of explosion.
Use water spray to cool unopened containers.
Remove undamaged containers from fire area if it is safe to do
so.
Evacuate area.
Special protective equipment
for fire-fighters
:
Wear self-contained breathing apparatus for firefighting if
necessary.
Use personal protective equipment.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protec-
tive equipment and emer-
gency procedures
:
Evacuate personnel to safe areas.
Avoid skin contact with leaking liquid (danger of frostbite).
Ventilate the area.
Follow safe handling advice (see section 7) and personal pro-
tective equipment recommendations (see section 8).
Environmental precautions
:
Avoid release to the environment.
Prevent further leakage or spillage if safe to do so.
Retain and dispose of contaminated wash water.
Methods and materials for
containment and cleaning up
:
Ventilate the area.
Local or national regulations may apply to releases and dispo-
sal of this material, as well as those materials and items em-
ployed in the cleanup of releases. You will need to determine
which regulations are applicable.
Sections 13 and 15 of this SDS provide information regarding
certain local or national requirements.
SECTION 7. HANDLING AND STORAGE
Technical measures
:
Use equipment rated for cylinder pressure. Use a backflow