User manual

3 - 30
RemApnt.config
The file RemApnt.config stores the configuration information for the ReM Licensing tool, including
scanner name, scanner ID, and file paths for firmware, license and golden settings files. You can use the
ReM installer to generate the information for RemApnt.config or create the file manually.
Basic Layout
The layout of RemApnt.config is shown below:
[Rem Licensing]
ScannerName=
ScannerID=
FirmwareMain=
FirmwareMainPath=
FirmwareCoprocessor=
FirmwareCoprocessorPath=
GoldenSettingPath=
LicenseFilePath=
IsUseGoldenSetting=
IsFlashCoprocessor=
IsBootFlashCoprocessor=
IsFlashMainprocessor=
The table below explains each item contained in RemApnt.config:
Item Description
ScannerName The specific model of scanner. Optional.
ScannerID The scanner model ID (see page B-2). Required
FirmwareMain Main micro firmware number. Optional.
FirmwareMainPath Path of the main micro firmware, including file name. Required if
IsFlashMainProcessor is set to yes.
FirmwareCoprocessor Co-processor main micro firmware number. Optional.
FirmwareCoprocessorPath Path of the co-processor firmware, including file name. Required if either
IsFlashCoprocessor or IsBootFlashCoprocessor is set to yes.
GoldenSettingPath Path of the Golden Settings file, including file name. Required if
IsUseGoldenSetting is set to yes.
LicenseFilePath Path of the license file obtained from Honeywell, including file name.
Required.
IsUseGoldenSetting Whether you want the Golden Settings file downloaded to the scanner dur-
ing the licensing process. Required.
Possible values: yes or no.
IsFlashCoprocessor Whether you want the coprocessor firmware updated during the licensing
process. Required.
Possible values: yes or no.
IsBootFlashCoprocessor Whether you want to boot flash the co-processor firmware during the
licensing process. Required.
Possible values: yes or no.