User manual

3 - 19
Statistics Page Options
Click Stop Update to freeze the statistical information so that it does not update according to the
automatic refresh period (see page 3-7).
Click Save Log to generate a CSV file containing the following statistical information for all selected
scanners: IP address, scanner model, serial number, firmware number, logical device name, bar code,
bar code type, decode time, scan attempts, scan field, scan field count, scanner ID byte, stitched bar
code, zero status, stitched bar code count, bar code count, and primary interface. See Appendix C for
more information about ReM Reports.
To save a CSV file containing information for a single scanner:
Click Decode to save a log containing the following information about the bar codes scanned by
the scanner: bar code, code type, decode time, scan attempts, scan field used (if any), scanner
ID byte, stitched bar code, and zero status.
Note: See page B-4 for a list of bar code types.
Click Errors to save a log containing descriptions of any errors reported by a scanner (e.g., RAM
Error, Program Error, Configuration Error, Co-Processor Interface Error).
Note: Only the following models report error information: MS1690, MS2300, MS2400, MS5145,
MS7120, MS7180, MS7820, MS9520, MS9540, and MS9590. For descriptions of any error
conditions, please refer to the scanner’s documentation.
Decode Time (DT) The minimum, maximum and average time, in milliseconds, that the
scanner has taken to read previously scanned bar codes.
Scan Attempts (SA) The number of times the scanner attempted to scan a bar code before
a successful read.
Scan Field (SF) The field used to scan the last bar code: vertical plane, horizontal 1,
horizontal 2, or auxiliary device. This statistic applies only to scanners
that have more than one scan field (MS2300 and MS2400 only).
Scan Field Count The number of bar codes scanned in each Scan Field (MS2300 and
MS2400).
Scanner ID Byte (SB) Identifies the type of scanner. (MS and IS models only.)
Stitched Bar code (RE) Indicates whether or not the last bar code received was reconstituted
(stitched) from several partial scans. This statistics applies to Code
128 and the UPC family of bar codes only.
Zero Status (ZS) The state of the scale when the last bar code was read (MS2300 and
MS2400 only):
0 = the scale has zero weight
1 = the scale is not zero weight
Stitched Bar code Count The number of times that the scanner has reconstituted (stitched) a
complete bar code from several partial scans. (Code 128 and the UPC
family of bar codes only.)
Bar code Count The total number of bar codes scanned by the device since ReM instal-
lation.
Primary Interface How the scanner is attached to its host. For example: RS232, IBM
OEM USB.
Parameter Description