Spec Sheet

HGAS_HTRAMDatasheetEN | Rev A | 10/21
© 2021 Honeywell International Inc.
For more information
sps.honeywell.com
Honeywell Gas Analysis and Safety
9680 Old Bailes Rd, Fort Mill, SC 29707
(803) 8358000
Contact us
US: Canada:
Tel. 800.430.5490 Tel. 888.212.7233
Fax. 800.322.1330 Fax. 888.667.8477
informationsp@honeywell.com
SCENARIO SELECTION
The device has three pre-programmed scenario settings
based on activity levels.
Low activity: Reading, quietly talking, Breathing rate
(susceptibles): 0.252 m3/h, CO
2
emission rate/person:
0.0052 (@ 273 K and 1 atm), Quanta exhalation rate
(infected): 9.4 quanta/h, activity duration for 30 minutes
Medium activity: Eating, talking loudly, Breathing rate
(susceptibles): 1.2 m3/h, CO
2
emission rate/person: 0.012
(@ 273 K and 1 atm), Quanta exhalation rate
(infected): 170 quanta/h, activity duration for 45 minutes
High activity: Running, jumping, exercising, Breathing rate
(susceptibles): 3 m3/h, CO
2
emission rate/person: 0.016 (@
273 K and 1 atm), Quanta exhalation rate
(infected): 408 quanta/h, activity duration for 60 minutes
Other general assumptions from risk estimator can be
found in the below table:
Parameters Value Unit Source
Width of room
Length of room 30 ft
30 ft
Volume
900sq ft
Height
16 ft
Background CO2 Outdoors
415 ppm
Temperature
Pressure 0.95 atm
20 C
Relative Humidity
50 %
Deposition to surfaces
Decay rate of the virus default per:https://tinyurl.com/covid-estimator
default per:https://tinyurl.com/covid-estimator
default per:https://tinyurl.com/covid-estimator
default per:https://tinyurl.com/covid-estimator
0.62h-1
0.3 h-1
Total N people present
20 ft
Additional control measures
0h-1
Fraction of population immune
Infected People1person
0%
Exhalation mask efficiency
0%
Inhalation mask efficiency
Fraction of people w/ masks 0%
0%
no mask
no mask
no mask
The default setting is the low activity setting with the alarm threshold of
800 ppm for medium and 1100 ppm for high.
Quanta Concentration
initial value
0.00no virus at the beginning
* The Honeywell Transmission Risk Air Monitor (HTRAM)
analyzes specific air quality conditions and alerts the user
when conditions are present that may increase risk of
potential exposure to airborne viral transmission. It does
not prevent or reduce virus transmission nor mitigate
viruses that may be present, nor does it detect or warn
against the presence of any virus, including but not limited
to COVID19. Even at lower risk levels caution is required
to prevent viral transmission. The HTRAM does not repel or
destroy any microorganism, viruses, bacteria, or germs.
It is buyer’s sole responsibility (1) to determine the suitability of
the HTRAM for use in its application; (2) to operate the HTRAM
in accordance with the User Manual and any other instructions
provided by Honeywell and in compliance with all applicable laws,
rules and regulations; and (3) to determine, based on buyer’s
experience, expertise, and other available tools, the suitability of
any product or service it may offer or recommend to the end user.
Buyer is responsible for determining whether the product is
appropriate for use under certain international, federal, state
or local guidelines, and is likewise responsible for determining
whether the HTRAM qualifies for any government programs,
including without limitation, reimbursement plans.
Any recommendations or assistance provided by Honeywell
regarding the use or operation of the HTRAM – through our
literature, the Honeywell web site, or otherwise – shall not be
construed as representations or warranties of any kind, express or
implied, and such information is accepted at buyer’s own risk and
without any obligation or liability to Honeywell.
The information we supply in this data sheet is believed to be
accurate and reliable as of this writing. However, specifications
may change without notice, and Honeywell assumes no
responsibility for its use.
The HTRAM does not detect for levels of CO
2
that would make for
an unsafe or unsuitable breathing environment.
1 https://tinyurl.com/FAQ-aerosols
2 https://leginfo.legislature.ca.gov/faces/codes_displayText.xhtm-
l?lawCode=PUC&division=1.&title=&part=1.&chapter=8.7.&arti-
cle=3
3 https://pubs.acs.org/doi/10.1021/acs.estlett.1c00183
4. The HTRAM’s preset PPM measurements for each activity level
are subjective standards based on Honeywell’s assessment of
U.S. state tatutory limits and scientific studies, including the
“2020 COVID19 Aerosol Transmission Estimator” and the
“Exhaled CO2 as a COVID19 Infection Risk Proxy for Different
Indoor Environments and Activities” article from the University
of ColoradoBoulder (see https://docs.google.com/spread-
sheets/d/16K1OQkLD4BjgBdO8ePj6ytfRpPMlJ6aXFg3PrIQB
bQ/edit#gid=519189277 and https://pubs.acs.org/doi/10.1021/
acs.estlett.1c00183, respectively) . The user must verify applicable
standards or regulations and adapt the product’s thresholds to
such standards and regulations as required for its usage intended
by the user.
5. Please note: A green designation does not mean no risk for
transmission. An increase from green to yellow, yellow to red or
green to red does not indicate a linear increase in potential trans-
mission risk within one activity setting. Any increase in potential
transmission risk across multiple activity settings is also not linear.
Numerous factors, including without limitation, interaction among
individuals in a room, the number of infected individuals present,
and the wearing of Personal Protective Equipment (PPE) such as
masks and gloves, will affect the potential transmission risk. Users
should not rely solely on this device to make a determination of
safety.
6. Percent of infection risk calculation is based on the following
assumptions and is only intended as guidance: Total number of
people: 20, Infected: 1; Time duration: 30 mins and room size: 900
sq ft.
7. Percent of infection risk calculation is based on the following
assumptions and is only intended as guidance: Total number of
people: 20, Infected: 1; Time duration: 45 mins and room size: 900
sq ft.
8. Percent of infection risk calculation is based on the following
assumptions and is only intended as guidance: Total number of
people: 20, Infected: 1; Time duration: 60 mins and room size: 900
sq ft.
WARRANTY
Under normal use and maintenance that is consistent with
Honeywell manuals and instructions, Honeywell warrants
that, for a period of one (1) year from the date of purchase,
all components of this product, except software and
software components, shall be free from faulty workmanship
and defective materials. The software and software
components, including any documentation designated
by Honeywell for use with such software or software
components, are provided “AS IS.
These warranties do not apply if the claimed defect or
nonconformity is due to accident, misuse, neglect; or
improper shipping or handling, installation, or testing; or
any failure of electrical power, air conditioning, or humidity
control. This warranty is valid only if the product has not
been tampered with or serviced by any party not authorized
by Honeywell.
If during the one-year warranty, the customer notifies
Honeywell in writing of any alleged defect within 30 days
of discovery, and it is determined by Honeywell that any
component of the product, except software components, is
defective due to faulty workmanship or defective materials,
then Honeywell shall repair or replace such Product at
Honeywell’s sole discretion. Repair or replacement of a
product (or any part thereof) does not extend the warranty
period for such product. Products which have been repaired
or replaced during the warranty period are warranted for the
remainder of the unexpired portion of the original warranty
period.
In case of non-conforming products, users may return such
product to the distributor where they made the original
purchase.
Honeywell shall not be responsible for any loss or damage
of any form, including any accidental or necessary direct
or indirect loss as a result of breach of any warranty or any
other acts that damage the product.
These explicit warranties are the only warranties provided by
Honeywell with respect to the product and are in lieu of all
other warranties, express or implied. Any implied warranty or
guarantee, including merchantability, fitness for a particular
purpose, and non-infringement of third party rights, shall
not apply.
This warranty only applies to the main unit of the product,
and does not cover the package, manuals, consumables, or
other components susceptible to damage or consumption
or which have a normal life inherently shorter than the
foregoing warranty period.
Customers wanting additional warranty beyond the standard
one-year warranty offered by Honeywell have the option
to purchase a 2-year extended warranty when purchasing
the product. Any such extended warranty shall only extend
the timeframe of the warranty terms above from three
years from the date of purchase, and shall not provide any
additional warranty or guarantee, express or implied.
DISPOSAL
This product contains a lithium-ion battery and aluminum
alloy materials. Upon receipt of the product, the customer is
responsible for proper use, transport, storage and disposal of
the product based on the battery and material type, including
but not limited to applicable governmental requirements for
proper disposal
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
MANUFACTURER CERTIFICATE
Honeywell Safety and Productivity Solutions certifies that
the CO
2
sensor in Honeywell Transmission Risk Air Monitor
(HTRAM) device is maintenance-free in normal indoor envi-
ronments. No calibration at end user is needed. The accuracy
of the sensor is ±50 ppm at 1000 ppm CO
2
.
SIMPLIFIED EU DECLARATION OF
CONFORMITY
Hereby, Honeywell Safety and Productivity
Solutions declare that the radio equipment type
HTRAMV2W is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address:
https://sps.honeywell.com/us/en/products/safety/-gas-
and-flame- detection/portables/honeywell-transmis-
sion-risk-air-monitor
Operating Frequency: 24002483.5 MHz (Bluetooth):
<20 dBm EIRP; 24002483.5 MHz (WLAN IEEE 802.11b/g/n):
<20 dBm EIRP.
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interfer-
ence, and
(2) this device must accept any interference received, includ-
ing interference that may cause undesired operation.
SIMPLIFIED UK DECLARATION OF
CONFORMITY
Hereby, Honeywell Safety and Productivity
Solutions declare that the radio equipment type
HTRAMV2W is in compliance with UK radio
equipment regulation. The full text of the UK
declaration of conformity is available at the following internet
address:
https://sps.honeywell.com/us/en/products/safety/-gas-
and-flame- detection/portables/honeywell-transmis-
sion-risk-air-monitor
United Kingdom Contact: Life Safety Distribution GMBH.
Address: Hatch Pond House, 4 Stinsford Road,
Nuffield Industrial Estate, Poole, Dorset, BH17 0RZ, UK.
Phone: +41 (0)44 943 4300
RECHARGEABLE LI-ION BATTERY
Nominal Voltage: 3.6 V
Rated Capacity: 2480 mAh/8.93 Wh
Typical Capacity: 2600 mAh/9.36 Wh
Limited Charging Voltage: 4.2 V
Manufacturer: SCUD (Fujan) Electronics Co., Ltd.
Red Wire: (+) Black wire: (-)
Made in China
WARNING: TO PREVENT INJURY, DO NOT
DISASSEMBLE,PUNCTURE, CRUSH, HEAT, OR BURN
Use the authorized charger only. Never disassemble by
yourself. Never short-circuit the battery. Dispose of the battery
properly. Exposing the battery to an open flame could cause
an explosion.
802.11 CAUTION
Users are responsible for configuring the channels of oper-
ation that comply with their country regulatory standards. A
Wireless Network Administrator should review the operationg
restrictions for the access point.
Strangulation HAZARD: Children have STRANGLED in cords.
Keep this cord out of reach of children (more than 3 ft (1m)
away). Do not use with an extension cord.