Parameter list
Parameter Description Available Settings
1 language
Display language
Sets the language of the interface on the display
1 ... 6
2
= English*
2 backlight
Display backlight
Sets whether or not the display backlight comes on when
the adjustment dial is turned or the button is pressed
0
= Disabled
1
= Enabled*
3 win time
Auto window open duration
When an open window or door is detected the radiator
valve will be closed for this period of time
0
= Inactive
30
= Minutes*
90
= Minutes
4 win dec
Auto window open temperature fall rate
Rate at which the room temperature decreases before
Auto Window Open function closes the radiator valve
0.2 ... 2.0
0.8
= 0.8°C per min*
5 win inc
Auto window open temperature rise rate
Rate at which the room temperature rises before Auto
Window Open function opens the radiator valve
0.2 ... 2.0
0.2
= 0.C per min*
6 stroke
Valve stroke range
Sets the stroke range to suit the radiator valve
0
= Standard stroke*
1
= Full stroke
7 ROOMTEMP
Temperature display
Displays either the programmed set temperature or the
measured room temperature
0
= Set temperature*
1
= Room temperature
8 calibrate
Temperature offset
Adjusts the measured temperature to compensate for the
location of the radiator controller
-3 ... 3
0
= 0°C offset*
9 battery
Battery type
Sets the battery type used in the radiator controller -
Alkaline / Lithium / NiMH
0
= Alkaline*
1
= Lithium
2
= NiMH
10 valve pos
Valve position display
Briefly displays if the valve is open or closed when
enabled
0
= Disabled*
1
= Enabled
11 wi n typ e
Auto Window Open function
Automatic window open detection
0
= Disabled
1
= Enabled*
12 fullreset
Factory reset
Resets all parameter settings to factory default (does not
reset the stored binding data)
0
= Disabled
1
= Full reset*
13 exit
Press to exit the settings menu
*recommended settings