Installation guide

A A
' ',1 p 120vAo
IMECHANtCALI
HUM,DISTAT|_ HUMIDIF,ER
"4__
YELLOW WIRES
TO BLOWER
MOTOR
IGNITION BOX
Z_POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
Z_24V WIRING.
M12686
Fig. 5. Typical wiring diagram for humidifier using fan control to
cycle blower motor fan and humidifier simultaneously.
I MECHANICAL_ A
HU MIIDtSTAT | /2_
_ p 120 VAC
HUMIDIFIER Z_
YELLOW WIRES
/_ POWER SUPPLY.
PROVIDE DISCONNECT
MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
//_ 24V WIRING.
Mt2684
Fig. 6. Typical wiring diagram of current sensing relay with
humidifier.
I MECHANICAL_ /k
H UMIDtS_L_ _::::::_ 120 VAC
E,,OWW, ES
1 LN..za A POWERSUPPLYPROV,DEDISCONNECT
s A2ES ,. O/ERLOADPROTECT,ON
Z_24V WIRING. M12685
Fig. 7. Typical wiring diagram of sail switch with humidifier.
For H1008Automatic Humidity Controlwiring connections:
IMPORTANT
Current sensing relay or sail switch is not needed with the
Automatic Humidity Control.
Use 18-22 gauge insulated wire forproper wiring. We
recommend stranded - tinned wire.
1. Connect 24 Vac power to the 24 Vac HOT and COM terminals on
the H 1008A.
2. Connect the humidifier to the two HUM terminals on the H1008A
as shown in Fig. 8.
For additional mounting and wiring information, refer to the Humidity
Control installation instructions.
For Perfect Climate Comfort CenterTM Control connections:
1. Connect only the two yellow wires to the W8900 (red wire
connections are not used). See the typical wiring diagram in
Fig. 9.
For additional mounting and wiring information, refer to the Perfect
Climate Comfort Center TM installation instructions.
PlumbingSaddleValve
Hot or cold water, either hard or softened, can be used in the
humidifier.
1. Use the self-piercing saddle valve (included) to tap into the water
supply line at an appropriate location.
CAUTION
Chemical Hazard.
Can cause personal injury or equipment damage.
Do not use any line connected to an air conditioner.
IMPORTANT
The saddle valve is not designed to regulate water flow, the
valve is either open or closed.
To prevent debris from clogging the solenoid in-line filter, be
sure to install the saddle valve handle pointing toward the
ceiling.
NOTE: Lightly clean the copper tubing ends with fine
sandpaper before making any connections.
ROOM THERMOSTAT
A
120
VAC
A
AUTOMATIC HUMIDITY CONTROL FROST FACTOR
SETPOINT DIAL
CONNECTO_ SOLENOID
Z_ HEAT ONLY APPLICATIOtN SHOWN. SIMILAR WIRING
Z_ POWER SUPPLY. PROVIDE DISCONNECT MEANS REQUIRED tN HEAT AND COOL SYSTEM WITH ONE
AND OVERLOAD PROTECTION AS REQUIRED. OR TWO TRANSFORMERS.
Z_ 24v WIRING
FURNACE
TRANSFORMER
L1
(HOT)
M12820B
Fig. 8. Typical wiring diagram for humidifier using H1008A Automatic Humidity Control.
2.
3.
Use 1/4 in. O.D. copper tubing and connect the saddle valve to
the inlet side of the solenoid valve.
a. Place the brass compression nut over the copper tubing.
b. Slide the brass ferrule over the tubing.
NOTE: Do not over-tighten the compression nut. Moderate
tightness prevents leaking.
c. Insert the tubing into the solenoid valve fitting and support
the valve while tightening the compression nut.
NOTE: Slope hose downward for correct drainage.
Connect a 1/2 in. hose to the humidifier drain fitting and run it to
a suitable drain.
CHECKOUT
1. Open the saddle valve.
NOTE: The furnace blower must be on for the humidifier to
operate.
2. Set the thermostat setpoint 10°F (6°C) above the room
temperature.
3. Set the convertible humidity control to a high humidity setting, or
place the H1008AAutomatic Humidity Control in the test position.
4. Observe the water running out of the drain line to be sure the
humidifier is working correctly.
5. Check for leaks.
6. Reset the thermostat to a comfortable setting or the Automatic
Humidity Control to the desired frost factor setting.
PC8900
_HE36O I
120 /3\ >L
_) W8900B
CO2 $
®
®
1@
®1
RH___
®1
®
_OUT
®
LED
®
O/B
@G
$ ux
_w2
A
OPTIONAL
OUTDOOR
AIR SENSOR
Z_ POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
Z_ OPTIMAL CONTROL ACHIEVED WHEN USING OUTDOOR AIR SENSOR.
Z_RED WIRES ARE NOT USED tN THIS APPLICATION. MI2819A
Fig. 9. Typical wiring diagram for humidifier using PC8900/W8900.
Home and Building Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
69-1428 G.H. 8-00
Home and Building Control
Honeywell Limited-Honeywell Limitde
35 Dynamic Drive
Scarborough, Ontario
MIV 429
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
Honeywell
_rt
www.honeywell.com/yourhome/