Users Manual

GATEWAY (GW-1000-WE/GW-1000-NWE)
® U.S. Registered Trademark
© 2020 Honeywell International Inc.
31-00424 | Rev.10-20
Honeywell Building Solutions
Honeywell
715 Peachtree Street NE
Atlanta, GA 30308
customer.honeywell.com
buildingcontrols.honeywell.com
Professional Installation
This device must be professionally installed, this
should be noted on grantee.
To maintain compliance, only the antenna types that
have been tested shall be used, which listed in “Remote
Antenna Part Numbers” on page 6. This device requires
a significant technology engineering expertise towards
understanding of the tools and relevant technology, not
readily available to average consumer. Only a person
professionally trained in the technology is competent.
This device is not directly marketed or sold to general
public.
Safety Information as per EN60730-1
The GW-1000-WE/GW-1000-NWE Gateway is intended
for residential, commercial, and light-industrial
environments.
The GW-1000-WE/GW-1000-NWE Gateway is an
independently mounted electronic control system with
fixed wiring.
The GW-1000-WE/GW-1000-NWE is suitable for
mounting in fuse boxes conforming with standard
DIN43880, and having a slot height of max. 45 mm.
It is suitable for panel rail mounting on 35 mm standard
panel rail (both horizontal and vertical rail mounting
possible).
The GW-1000-WE/GW-1000-NWE is used for the purpose
of building HVAC control and is suitable for use only in
non-safety controls for installation on or in appliances.
Table 12. Safety Information as per EN60730-1
Electric Shock
Protection
PELV
Pollution Degree Pollution Degree 2, suitable for use
in industrial environments.
Installation Class 3
Overvoltage
Category
24 V-powered controls: Category I
Rated Impulse
Voltage
330 Vac for Category I (SELV)
Automatic
Action
Type1.Y
Software Class Class A
Enclosure IP20 according to EN-60529
Ball-pressure
Test
Temperature
>75 °C for all housing and plastic
parts
>125 °C in the case of devices
applied with voltage-carrying parts,
connectors, and terminals.
Electromagnetic
Interference
Tested at 230 Vac, with the
modules in normal condition.
System
Transformer
Europe: safety isolating
transformers according to
IEC61558-2-6
U.S.A. and Canada: NEC Class-2
transformers
WEEE
WEEE Directive 2012/19/EC Waste
Electrical and Electronic Equipment
Directive
At the end of the product life,
dispose of the packaging and
product in an appropriate recycling
center.
Do not dispose of the device with
the usual domestic refuse.
Do not burn the device.
Table 12. Safety Information as per EN60730-1