Installation Instructions
81
Galaxy 2 Series Installation Manual
44=Abort (Pulse)
The Abort output is activated when a valid code is entered to unset the system following an intruder alarm.
The output stays on for one minute and then switches off.
45=Unset (Pulse)
The Unset output is activated each time the system (or group) is unset.
51=Link (Reflex)
Activates when link zone is activated see 52.1
66=RF Jam (Reflex)
The RF Jam output is activated whenever any of the RF RIO’s configured onto the system detect a significant
level of interference to cause radio jamming.
67=RF Supervision Fail (Reflex)
The RF Supervision Fail output is activated whenever there is a supervision failure from any one of the
supervised RF detectors configured onto the system. That is, when the system has received no signals (includ-
ing periodic check-in signals) whatsoever, from a particular detector within the programmed supervision
period.
68=Assistance (Latch)
Keypad assistance hot key activation or assistance zone.
70=Any Set (Reflex)
Activated when system is Full Set, Part Set or Night Set.
71=Bell Fail (Reflex)
Activates when bell fail zone is activated see Option 52.1
72=RF TX Low Battery (Reflex)
The RF TX Low Battery output is activated whenever an RF detector sends a low battery condition to an
RF receiver.
76=Fault (Reflex)
This output will activate any time there is a fault condition present on the panel and will clear when all the fault
conditions have cleared.
The following fault types will activate the fault output:
Line fail (any module), ARC comms fail (any module), RF jam, RF low battery, RF supervision failure, Bell fail
(from a bell fail zone), AC fail (panel, AC zone or power supply), Battery fail (panel, battery zone or power
supply).
SMS signalling faults will not activate the fault outputs.
53 - Outputs (cont’d)