Galaxy 2 Series Installation Manual
52 - Zones (cont’d)
20 Tamper
The Tamper function is continuously operational. When a Tamper zone is activated (1k to 2k), a tamper
alarm is generated; this requires to be reset by an authorised user code. If a tamper condition (open or short
circuit) occurs, a tamper alarm is also generated.
23 Batt Fail
This function is used to monitor the voltage of a back-up battery connected to a power supply. It causes an
Aux. Power Supply fault condition.
25 AC Fail
This function is used to monitor a remote power supply. In the event of a power failure the AC Fail zone is
activated; the activation (+) and de-activation (–) of the zone is recorded in the event log.
53 Secondary Entry
As exit function but changes to entry upon the force omitting of a final zone.
54 Assistance
This function activates a “personal assistance required” alarm in both set and unset conditions. Bells and
sounders are activated and an assistance message is signalled.
55 Bell Fail
This function causes a bell fault condition.