Installation Instructions
72
Galaxy 2 Series Installation Manual
8. Exit ZN conf.
0 = Before Entry (default)
1 = Except Entry
9. Entry clears conf.
This options selects whether a single (unconfirmed) alarm activation is remembered for the purposes of confir-
mation, after an entry door is open. This option has two settings:
0 = Reset Count
In this case, the confirmed alarm counter is reset to 0 as soon as an entry door is opened.
1 = Keep Count (default)
In this case, the confirmed alarm counter is maintained. If there is one alarm activation before the entry
door is opened, and then another activation after the entry delay expires, a confirmed alarm condition will
be generated, provided that both activations occur within the confirm time window.
51 - Parameters (cont’d)