Installation Instructions

97
Galaxy 2 Series Installation Manual
Option 63 - Options
This menu has one sub-section:
1 = Groups
There are three sub-options:
1 = Group Mode
This option enables group mode. When enabled, each group on the system will behave as an independent
area that can be separately set and unset. There are two settings:
0 = Disabled
1 = Enabled
If a group mode is switched off, the system will behave as though all zones, users and outputs are in group 1.
63 - Options
GROUPS 123GROUPS 123
GROUPS 123GROUPS 123
GROUPS 123
Set YNNSet YNN
Set YNNSet YNN
Set YNN
2 = Common Group
Group 4 is intended to be a group that will cover a common access area (such as an entrance foyer). This
group will set and unset automatically depending on the state of the other individual areas. When all the other
individual areas are set, the common group will set along with the last group. As soon as any of the individual
groups are unset, the common group will unset. In order to determine which individual groups need to be set
before the common group sets, the group map in this option can be programmed. The screen is as shown
below. Pressing the appropriate group number toggles the group status between Y and N. A Y under a group
number means that that individual group needs to be set before the common group can set.
3 = Comms Set Map
This option selects which groups must be set before intruder communication can be enabled. This means either
full set, night set or part set. The screen should appear as follows:
GROUPS 1234GROUPS 1234
GROUPS 1234GROUPS 1234
GROUPS 1234
Set NNNNSet NNNN
Set NNNNSet NNNN
Set NNNN
This option only affects Set, Intruder, Confirm, Omit, Abort and the appropriate restore signals. All other
signalling is not part of the Intruder comms system.