Install Instructions
OPERATION
AND SERVICE
Slide out the Safety Screen and set aside.6.
Best cleaning tools: 2 in. (51 mm) wide (or greater) synthetic or natural bristle brush with a NOTE:
5 in. (157 mm) handle (see Fig. 18) or vacuum cleaner with brush attachment.
Gently stroke the ionization points on the top plane of each bar with enough brush depth to hit front 11.
and back tips of the points in the ionization array. Use a gentle back and forth brushing motion to
clean any small accumulations from the tips of the points. If desired, use vacuum cleaner with brush
attachment to gently vacuum the frame and components of enhancement module.
Reinstall the safety screen.12.
Slide the enhancement module back into cabinet.13.
Models 1620/2020/2520: 14. Reconnect the power cord and ow sensor cable (see Fig. 11 on page 15).
Models 1625/2025: Reconnect the power cord (see Fig. 15 on page 17).
Replace the Honeywell Enhanced Air Cleaner door.15.
Turn the Honeywell Enhanced Air Cleaner switch to the on position.16.
Turn heating and cooling system power on.17.
30°
POINTS ARESHARP!BE VERYCAREFUL DURING CLEANING.
IONIZER POINT WITH RESIDUE IONIZER POINT AFTER CLEANING
M29816
ENHANCEMENT MODULE
Fig. 18. Removal of deposits from ionization points.
Maintenance
TrueCLEAN™ Enhanced Air Cleaner 68-0308EFS—01
21