Install Instructions
WIRING
f. Attach the quick connect terminals to the furnace EAC-1 and EAC-2 spade connections, which are
polarity neutral.
g. Attach the ground ring to furnace chassis ground.
The 1625/2025NOTE: Honeywell Enhanced Air Cleaner is to be powered by 120 VAC at 60 Hz.
The Honeywell Enhanced Air Cleaner should only be powered when airow is present. The furnace NOTE:
control EAC spade connections provide power only when the furnace blower is operating. If EAC
connections are not available, an alternative airow sensing mechanism must be used to ensure the
Honeywell Enhanced Air Cleaner is only powered when airow is present. Contact a local Honeywell
distributor for information on alternative airow sensors.
Wiring the 1625/2025 (Furnace) Honeywell Enhanced Air
Cleaner
Before proceeding to Startup and Operation on page 19:
I wired the Honeywell Enhanced Air Cleaner as instructed.
1625/2025 Wiring is complete. Go to page 19.
TrueCLEAN™ Enhanced Air Cleaner 68-0308EFS—01
18